Sp6000 Peripherals - Ricoh BE-C1 D046 Field Service Manual

Table of Contents

Advertisement

8. Appendix: SP Mode Tables
[0 or 1 / 0 / 1/step]
0: Disable, 1: Enable
5990
SP Print Mode (SMC Print)
In the SP mode, press Copy Window to move to the copy screen, select the paper size,
then press Start. Select A4/LT (Sideways) or larger to ensure that all the information prints.
Press SP Window to return to the SP mode, select the desired print, and press Execute.
1 All (Data List)
2 SP (Mode Data List)
3 User Program Data
4 Logging Data
5 Self-Diagnostic Report
6 Non-Default (Prints only SPs set to values other than defaults.)
7 NIB Summary
8 Capture Log
21 Copier User Program
8
22 Scanner SP
23 Scanner User Program

SP6000 Peripherals

6117
Folder Input Check
This SP retrieves the SP settings of each bit within 0.5 sec., collects the data into 1-byte, then
sends it to the controller. However, undefined sensor information on the Folder unit side is set
to "0" without checking the Folder unit.
• If there is no response from the Folder FD within the prescribed time after it is checked, the
1-byte data (sensor information) is set to "0".
• The requests for engine information stop after this SP screen is closed.
200
(7) 0000 0000 (0)
GW

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Be-c1 d049

Table of Contents