(14) Hazard Switch

Hazard Switch
1. Remove the meter panel and disconnect the 4P connector from
hazard switch after disconnecting the battery negative code.
2. Remove the hazard switch.
3. Perform the following checking.
(1) Hazard Switch
Connector Voltage
1. Connect the battery negative code, then measure the voltage
with a voltmeter across the a terminal and chassis.
2. If the voltage differ from the battery voltage, the wiring harness
is faulty.
Voltage
a terminal – Chassis
(1) 4P Connector
(for Hazard Switch)
(2) 4P Connector (for Main Switch)
Hazard Switch Continuity
1. Measure the resistance with ohmmeter across the a terminal (1)
and c terminal (3), and across the d terminal (2) and e terminal
(4).
2. If the measurement is not following below, the hazard switch or
the bulb are faulty.
Resistance
a terminal – c terminal
(Switch at OFF)
Resistance
a terminal – c terminal
(Switch at ON)
Resistance
d terminal – e terminal
(Bulb)
(1) a Terminal
(2) d Terminal
(3) c Terminal
9-S26
ELECTRICAL SYSTEM
9Y1210003ELS0035US0
Approx. battery voltage
a to e:Terminals
9Y1210003ELS0036US0
Infinity
0 Ω
Approx. 13 Ω
(4) e Terminal
(5) Bulb
9Y1210003ELS0037US0
KiSC issued 05, 2012 A