Power Failure Transfer - Panasonic KX-NS500 Features Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-NS500:
Table of Contents

Advertisement

5.6.2 Power Failure Transfer

5.6.2 Power Failure Transfer
Description
When the power supply to the PBX fails, specific SLTs are automatically connected to specific trunks (Power
Failure Connections). The PBX will switch from normal operation to the Power Failure Connections, and all
existing conversations will be disconnected.
Only the trunks handled by Power Failure Connections can be used during a power failure.
Conditions
Only trunk calls can be made during a power failure. All other features do not work.
The following SLT ports and LCOT ports are connected during a power failure. It is possible to allow trunk
calls that are established during a power failure to be maintained even when the power returns and the
connection is switched back to the normal configuration from the Power Failure Connection.
Main Unit
Expansion Unit
Installation Manual References
4.12 Power Failure Connections
552
Feature Guide
Port 1 on pre-installed MCSLC16 and port 1 on pre-installed
LCOT6
Port 2 on pre-installed MCSLC16 and port 2 on pre-installed
LCOT6
Port 1-4 on pre-installed MCSLC16 and port 1-4 on LCOT6 (if
two cards are installed, the lower numbered card is used).

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-ns300

Table of Contents