13.3 [11-3] Power Failure Transfer
13.3 [11-3] Power Failure Transfer
When the power supply to the PBX fails, power failure transfer (PFT) switches the current connections to
Auxiliary Connections, so that certain SLTs and CO lines can be connected. Auxiliary Connections allow CO
line calls to be made during a power failure. One CO line card and one extension card that are physically
connected by RJ45 cable can be specified. The conversations through the lines specified here will be
maintained even when the power returns.
Trunk Card Slot No.
Specifies the position of the CO line card to be used.
Default
None
Value Range
None, Small Free Slot 1, Small Free Slot 2, Small Free Slot 3, Small Free Slot 4 (KX-NCP1000 only)
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Manual References
13.1.11 Power Failure Transfer
Extension Card Slot No.
Specifies the position of the extension card to be used.
Default
None
Value Range
None, Small Free Slot 1, Small Free Slot 2, Small Free Slot 3, Small Free Slot 4 (KX-NCP1000 only)
Maintenance Console Location
13.3 [11-3] Power Failure Transfer
Programming Manual References
None
Feature Manual References
13.1.11 Power Failure Transfer
832
PC Programming Manual
Document Version 2009-12