Smart Touch: Wireless Edge, Wireless Gate Link - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
t
mart
oucH
A transmitter (MGL-TX20) and receiver (MGL-RX20) are
required. Refer to table on page 6.
1. Turn OFF power.
2. Connect the wiring per the diagram shown.
3. Turn ON power and access the Installer Menu.
4. Configure SENSOR setting accordingly (i.e.
Edge Open, Edge Close, or Edge Both). Refer
to table on page 10.
Refer to site scenarios on pages 20 and 24. Follow
instructions that accompany the device.
CAUTION
All external entrapment protection
sensors must be NC sensor outputs
and wired to the SENSOR COM
terminal for monitoring and powering
purposes. The sensor becomes actively
powered when the gate operator's
motor runs.
NOTE: In bi-parting swing gates,
CH1 and CH2 may be programmed
to the same SENSOR # TYPE on
one controller, but each CH must
be connected to separate SENSOR
inputs. Always make sure that a gate
edge is installed on each bi-parting
swing gate.
Be aware. Issues with radio interference
cause false trips. Placing the antenna
high and reducing environmental
"noise" is critical to proper wireless
transmission. Avoid placing the
receiver sets within 100 feet of each
other as crosstalk may occur.
NOTE: Use Miller Gate Edges
that have a wire marked with
Tape. The
Blue Tape
indicates a
resistor is built in. Use receivers
and transmitters, labeled Version
1.02 or higher.
Miller Edge LEARN mode. Press
the LEARN button on the Receiver
for 2 seconds until the amber light
blinks continuously. Press the Edge
or Test button on the Transmitter
to complete the LEARN mode
process and sync the receiver and
transmitter.
www.hysecurity.com © 2016
: w
e
IreLeSS
Power Supply Board
Connect either channels
output (P/NC wire) to
SENSOR 1, 2, or 3.
Blue
Red (Channel 1 &
Yellow
Channel 2)
Green
Wireless Edge Link (Receiver)
MGL - RX20
Signal received from battery-
powered Transmitter (MGL - TX20)
, w
dGe
IreLeSS
Installer Menu showing SENSOR 2 set to EDGE OPEN (Option #5) and
SENSOR 3 set to EDGE CLOSE (Option #3)
S2 0
SENSOR #2 TYPE
S2 5 (EDGE OPEN)
SENSOR #2 TYPE
1
2
3
4
5
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
LIMIT
Quick Start
G
L
ate
InK
S3 0
SENSOR #3 TYPE
S3 3 (EDGE CLOSE)
SENSOR #3 TYPE
POWER
DRIVE
STOP BUTTON
OPEN BUTTON
CLOSE BUTTON
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
OPEN PARTIAL
INTERLOCK OPEN
TIME CLOCK OPEN
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
VEHICLE DETECTOR
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
SENSOR
COM
DO NOT USE
SENSOR 2
DO NOT USE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
HySecurity
LOCK INTERLOCK
MX000585
VERSION
S/N
EMERG CLOSE
FIRE DEPT OPEN
Smart Touch Controller
LED
DUAL GATE
RADIO OPTIONS
RPM
COM
A
B
COM
OPEN
+24V
D0726 Rev. J
RS485
COM
NO
STATUS
S 1
+24V
COM
31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents