Smart Dc: Photo Eye / Reflective (E3K R10K4) - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
dc: p
mart
1. Set Photo Eye switch to LIGHT ON.
2. Turn OFF AC power.
3. Connect photo eye wiring.
NOTE: Run a jumper between photo eye -24V and
Relay COM (C2) terminals. See photo.
4. Turn ON power.
NOTE: Make sure both AC & DC switches are ON and the red battery
wire is plugged in.
5. Access the Installer Menu. Configure SENSOR
setting accordingly. For example, Eye Close,
Eye Open, or Eye Both.
CAUTION
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes. The
sensor becomes actively powered when the gate
operator receives a run command.
NOTE: Light/Dark switch
must be set to LIGHT ON.
Jumper -24V to Relay COM
(Terminal 6, C2)
COMMON / NEG. to SENSOR COM
Relay NO (Terminal 5, NO2) to SENSOR on Smart DC
www.hysecurity.com © 2016
e
/ r
Hoto
ye
+24V
(e3K r10K4)
efLectIVe
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
11
SENSOR 2
OPEN
EYE
10
SENSOR 3
EXIT
EXIT
9
LOOP
LOOP
BLOCK
8
EXIT
EXIT
IN OBS
7
LOOP
LOOP
OUT OBS
6
LOOP
LOOP
CENTER
5
LOOP
LOOP
EDGE
4
SENSOR 1
EYE
SENSOR
3
COM
COM
2
+ 24 V
EMERG
1
OPEN
SHOW
LEDs
NOTE: If you receive an Alert, "!ACTION BLOCKED"
"Photo Eye Open" PEO or "Photo Eye Close" PEC, take
steps to align the photo eye. Refer to Photo Eye
Alignment on page 12.
Quick Start
Installer Menu Settings
S1 0
SENSOR #1 TYPE
OPEN
CLOSE
STOP
MENU
S1 4 (EYE OPEN)
PREV
NEXT
SELECT
SENSOR #1 TYPE
OPEN
CLOSE
STOP
MENU
PREV
NEXT
SELECT
D0726 Rev. J
RESET
RESET
39

Hide quick links:

Advertisement

Table of Contents
loading