Smart Touch: Wireless Edge Gate Link & Photo Eye - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
t
mart
oucH
The wiring diagram illustrates a wireless edge receiver and a photo eye connection. For photo eye alignment, refer
to page 12.
CAUTION
Connect all contact and non-contact sensors
to same power source. Example, Do NOT
connect photo eyes to +24VDC and gate
edges to +12VDC. Incompatible electricity
flow. A FAULT 2 will appear.
EMX IRB MON Photo Eye
Transmitter
COMMON / NEG. to SENSOR COM
CAUTION
Set DIP Switches
1 = OFF
2 = OFF
3 = OFF
4 = ON
NOTE: DIP switches must
be set as shown otherwise
the photo eye will not
operate correctly. For easy
photo eye alignment, refer
to page 12.
Jumper POWER INPUT - 24V to
COM in Receiver
Miller Edge 2 Channel Wireless
Receiver (MGL - RX20)
COM
Green
POWER
* P / NC
10K
Yellow
STATUS
COM
* P / NC
10K
POWER
CH 1
CH 2
Antenna
OUTPUT
SELECT
www.hysecurity.com © 2016
: w
L
e
Ire
eSS
Power Supply Board
Photo Eye
Transmitter
+24V
+24V
COM attaches to
SENSOR COM
*Sensor wire (P/ NC) can
attach to any SENSOR
input.
CH 1 and CH 2 "LEARN" buttons. To identify and sync to one active transmitter, follow
manufacturer's installation instructions. Use receivers & transmitters Version 1.02 or higher.
DIP switches for CH1 and CH2. Verify dip switch is set to "R" for each channel used. HySecurity uses NC
"Relay" sensors. Do NOT select "P" as the output. P = "Pulse" device.
G
L
dGe
ate
InK
1
2
3
4
5
MGL - RX20
+24V
6
7
8
9
10
11
12
14
15
16
17
18
19
20
21
22
23
24
LIMIT
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes.
The sensor becomes actively powered when the
gate operator's motor runs.
+24V
To SENSOR COM
Quick Start
& p
Hoto
Configure Installer Menu items:
SENSOR 1, 2, & 3
S1 0
SENSOR #1 TYPE
DRIVE
POWER
STOP BUTTON
OPEN BUTTON
S1 2 (EYE CLOSE)
CLOSE BUTTON
SENSOR #1 TYPE
REMOTE OPEN AND
RADIO CONTROL
OPEN/CLOSE
OPEN PARTIAL
S2 0
INTERLOCK OPEN
TIME CLOCK OPEN
SENSOR #2 TYPE
FREE EXIT DETECTOR
DISABLE EXIT DETECTOR
DISABLE CLOSE TIMER
INSIDE OBSTRUCTION
S2 1 (NOT USED)
VEHICLE DETECTOR
SENSOR #2 TYPE
OUTSIDE OBSTRUCTION
VEHICLE DETECTOR
SHADOW/RESET
VEHICLE DETECTOR
SENSOR 1
S3 0
SENSOR
COM
SENSOR #3 TYPE
DO NOT USE
SENSOR 2
S3 5 (EDGE OPEN)
DO NOT USE
SENSOR #3 TYPE
SENSOR 3
DO NOT USE
CHARGER
AC LOSS
HySecurity
LOCK INTERLOCK
MX000585
VERSION
S/N
EMERG CLOSE
FIRE DEPT OPEN
Smart Touch Controller
LED
RADIO OPTIONS
DUAL GATE
RPM
COM
A
B
COM
OPEN
+24V
CAUTION
D0726 Rev. J
e
ye
RS485
COM
NO
STATUS
S 1
+24V
COM
33

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents