Site Assessment & Gate Design For Monitored Entrapment - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
a
Ite
SSeSSment
continued...
Eye Open
NOTE: Any gap larger than 2¼" (57 mm) between gate and
fixed objects must be protected. Install edge sensors where
gap between post and gate creates a draw-in zone.
Slide Gate: Monitored Entrapment Site Scenario (Viewing from SECURE side)
Eye Open
Retro-reflective
photo eye shown
Edge Both
SECURE
Swing Gate: Monitored Entrapment Site Scenario (Viewing from SECURE side)
NOTICE: UL 325 Standard of Safety provides the MINIMUM safety standards. Site, gate hardware usage, and
other conditions may dictate the use of additional safety designs/components. It is up to the gate system
designer and installer to assess appropriate safety design and components above and beyond minimum UL 325
and ASTM F2200 standards. Always check your local area codes and comply with all regulations.
www.hysecurity.com © 2016
& G
d
ate
eSIGn for
SECURE
Edge Both
Wrap around edge
sensor example
m
onItored
Edge Open
Check gap & protect
potential draw-in zones
Eye Close
Eye Close
Quick Start
e
ntrapment
PUBLIC
PUBLIC
D0726 Rev. J
17