Smart Dc: Mgl-Rx20 Wireless Gate Link - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

S
dc: mGL-rX20 w
mart
A transmitter (MGL-TX20) and receiver (MGL-RX20) are required (Version 1.02 or higher).
1. Turn OFF AC power.
2. Connect the wiring per the diagram shown.
3. Turn ON power.
4. Access the Installer Menu. Configure
SENSOR setting accordingly For
example, Edge Open, Edge Close, or
Edge Both.
5. Follow instructions that accompany the
device.
CAUTION
All external entrapment protection sensors must be
NC sensor outputs and wired to the SENSOR COM
terminal for monitoring and powering purposes. The
sensor becomes actively powered when the gate
operator receives a run command.
NOTE: Miller Edge LEARN mode. Press the LEARN button on the
Receiver for 2 seconds until the amber light blinks continuously.
Press the Edge or Test button on the Transmitter to complete the
LEARN mode process and sync the receiver and transmitter.
Yellow
Green
Wireless Edge Link (Receiver) MGL - RX20
Signal received from battery-powered
Transmitter (MGL - TX20)
42
D0726 Rev. J
OPEN
PREV
Connect either
channels output
(P/NC wire) to
SENSOR 1, 2, or 3.
Red (Channel 1
& Channel 2)
UL 325 - 2016 HySecurity Monitored Sensors
G
IreLeSS
ate
Installer Menu Settings
Examples in displays show
bi-parting swing gate site scenario.
Configuring SENSOR 2
S2 0
SENSOR #2 TYPE
CLOSE
STOP
MENU
RESET
S2 6 (EDGE BOTH)
NEXT
SELECT
SENSOR #2 TYPE
OPEN
CLOSE
STOP
MENU
RESET
PREV
NEXT
SELECT
COM
COM
COM
COM
COM
COM
COM
COM
STOP
OPEN
CLOSE
OPEN
P ARTIAL
11
SENSOR 2
OPEN
EYE
10
SENSOR 3
EXIT
EXIT
9
LOOP
LOOP
BLOCK
8
EXIT
EXIT
IN OBS
7
LOOP
LOOP
OUT OBS
6
LOOP
LOOP
CENTER
5
LOOP
LOOP
EDGE
4
SENSOR 1
EYE
SENSOR
3
COM
COM
+ 24 V
2
EMERG
1
OPEN
SHOW
LEDs
NOTE: In bi-parting swing gates, CH1 and CH2 may be
programmed to the same SENSOR # TYPE on one controller,
but each CH must be connected to separate SENSOR inputs.
Always make sure that a gate edge is installed on each bi-
parting swing gate.
L
InK
Configuring SENSOR 3
S3 0
SENSOR #3 TYPE
OPEN
CLOSE
STOP
S3 6 (EDGE BOTH)
NEXT
SELECT
PREV
SENSOR #3 TYPE
OPEN
CLOSE
STOP
PREV
NEXT
SELECT
NOTE: One wireless edge receiver
has the NC connections for up to
two wireless edge transmitters. Use
Miller Gate Edges that have a wire
marked with
Blue Tape.
indicates a resistor is built in. To avoid
crosstalk, use receivers & transmitters
Version 1.02 or higher.
© 2016 www.hysecurity.com
MENU
RESET
MENU
RESET
The
Blue Tape

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents