Table 6: Setting the Sensor Logic

External entrapment protection sensors can be wired to any one of the three sensor inputs on the HySecurity Controller.
The sensor logic, such as Eye Close Logic (EC), Eye Open Logic (EO) and Gate Edge Logic (GR) remain accessible in
the Installer Menu, if the corresponding sensor type is installed, and determine how the gate operator will react when a
monitored sensor is activated.
NOTE: Default settings shown in Bold.
Installer Menu
0 = Close eye stops only
EC 0 STOP ONLY
EYE CLOSE LOGIC
1 = Two second reversal to open
on swing, slide, or vertical gates.
Reverse to full open with barrier
gates, StrongArm M30 and
StrongArm M50.
2 = Reverse to full open.
EO 0 STOP ONLY
0 = Open eye stops only
EYE OPEN LOGIC
1 = Two second reverse to close
0 = Edge reverses fully open
GR 0 FULL OPEN
GATE EDGE LOGIC
1 = Two second reversal only
SR 1 REVERSE 25
0 = IES reverses fully open
1 =
REVERSAL LOGIC
PC 0 NO INPUT
0 = Normally Open NO input
PHOTO EYE OUTPUT
1 = Normally Closed NC input
(monitored)
GC 0 NO INPUT
0 = Normally Open NO input
GATE EDGE OUTPUT
1 = Normally Closed NC input
(monitored)
NOTE: The shaded Installer Menu items do not appear when Build Year is set to 2 (BY 2), post-2016. Exceptions exist for barrier
arms, CRASH products, operators set to pre-2016 and Usage Class 4 provisions.
www.hysecurity.com © 2016
Setting Options
second reversal only
Two
Menu Tasks & Explanations
If the close photo eye is triggered, the default
setting is non-reversal while the gate is traveling
in the close direction. When triggered, with the
optional setting of EC 1, the gate pauses and
reverses it's direction for a 2-second interval,
and then resumes moving in the close direction
if the photo eye clears within 5 seconds. (See
exception for barrier arms.) A setting of EC 2
causes the gate to reverse and travel full open
when triggered.
If the open photo eye is triggered, the default
setting is non-reversal while the gate is traveling
in the open direction. When triggered, with the
optional setting of EO 1, the gate pauses and
reverses it's direction for a 2-second interval, and
then resumes moving in the open direction if the
photo eye clears within 5 seconds.
The default setting is to reopen fully if the edge
sensor is triggered while closing. The optional
setting of GR 1 sets the gate to a 2-second
reversal if triggered while closing.
If the inherent sensor is triggered, the default
setting reverses the gate travel for a 2-second
duration. The optional setting of SR 0 will cause
the gate to reopen fully if triggered while closing.
Changes occurring in 2016.
The default setting is for photo eyes with
Normally Close outputs. When set for NC, the
connection is monitored and any short circuit
fault will generate a FAULT 2 (FAL2) alert. Press
the Stop or Reset button to clear.
See NOTE.
Changes occurring in 2016.
The default setting is edge sensor with Normally
Closed (NC) output. The optional setting of 0
requires an (NO) output.
See NOTE.
Quick Start
STC Wire
Connections
Sensor 1, 2, or 3
Sensor COM
COM
+24V
Sensor 1, 2, or 3
Sensor COM
COM
+24V
Sensor 1, 2, or 3
Sensor COM
+24V
10K resistor
(Edge)
N/A
EYE Close
EYE COM
4 wires total:
COM
+24V
COM
PHOTO EYE
CLOSE
EDGE SENSOR
COM
4 wires total:
COM
+24V
COM
EDGE
D0726 Rev. J