Diagram 1: Typical Slide Gate Site Assessment - HySecurity UL 325 Quick Start - Supplemental Instructions

Table of Contents

Advertisement

d
1: t
IaGram
NOTE: This scenario shows a possible configuration with the minimum recommended external entrapment protection sensors.
Other sensor configurations are valid. Each gate site is different. It is the installer's responsibility to assess and protect all
entrapment zones.
Photo eye thru-beam
protecting Trailing End of
gate (Open direction of
travel)
NOTICE: HySecurity slide gates are equipped with a Type A inherent entrapment sensor (IES) that complies with
UL 325. Any impediment to gate travel causes the gate to stop and reverse.
Monitored external entrapment protection sensors, which can be used in this site scenario and are compatible with
HySecurity slide gates, appear in the following chart. For a full list, refer to page 6.
EXAMPLE: External Entrapment Protection Sensors: Normally Close Contact, Compatible with HySecurity Gate Operators
P/N
2016 Monitored Sensors
Wired Gate Edge Sensor
MX3981
MGR20-2U-05-T2, Round
MX3983
Gate Edge Module (GEM -104)
MX3990
IRB-MON (Dist.~ 65 ft)t
MX3990
IRB-MON (Dist.~ 65 ft)
A minimum of one monitored external entrapment protection sensor, in addition to the slide gate operator's inherent
sensor, is required before enabling momentary control activation. However, if there is a risk of entrapment in both
directions of gate travel, then both directions of travel must be protected by an external sensor.
NOTE: At minimum, external entrapment protection sensors must be installed wherever potential for entrapment exists during gate
movement. Note that every site is different. All potential entrapment zones should be protected with contact or non-contact
sensors. HySecurity gate operators detect NC output sensors and monitor them to comply with UL 325 Standard of Safety.
www.hysecurity.com © 2016
S
ypIcaL
LIde
(5 ft for 2" round post)
Edge Interface Module
Thru-beam photo eye
Thru-beam photo eye
G
S
a
ate
Ite
Edge sensor
(protecting open
direction) Draw-in
zones
Photo eye thru beam
protecting Leading End of
gate (Close direction of travel)
Sensor Type
Output
Wraparound edge
Resistor
Normally
Closed
Normally
Closed
Normally
Closed
Quick Start
SSeSSment
Drawing is not to scale
Manufacturer
10K
Miller Edge
EMX Industries
EMX Industries
D0726 Rev. J
UL 325
Recognized
Type B2
Type B1
Type B1
19