The site designer or installer must determine which external entrapment protection sensors will be installed
with the gate operator to create a UL 325 compliant installation site.
NOTE: Table 3 provides the list of sensors that are approved for use with HySecurity gate operators using the monitoring
capabilities found in software versions h4.50 or h5.50 (or higher).
CAUTION
Temperatures and environmental conditions affect proper operation of external entrapment protection sensors.
Always check the manufacturer's specifications shipped with the sensors.
External Entrapment Protection Sensors: Normally Closed Contact, Compatible with
P/N
2016 Monitored Sensors
Wired Gate Edge Sensor
MX3981
MGR20-2U-05-T2, Round
2 CH Gate Edge Module
MX4161
(GEM-204)
Wired Gate Edge Sensor
MX3982
MGS20-2U-05-T2, Square
2 CH Gate Edge Module
MX4161
(GEM-204)
KIT: Wired Gate Edge Sensor
MX4037
MGO20-2E-05-T2, Square
and Channel mount
MX4161
2 CH Gate Edge Module
(GEM-204)
Reflecti-Guard (RG-R)
MX3985
KIT: MGL-K20
MX4015
(includes MX3986 and MX4013)
Wireless Gate Link
MX3986
MGL-TX20
Wireless Gate Link
MX4013
MGL-RX20
The Solution, MIM-62
MX3987
IRB-MON (Dist.~ 65 ft)
MX3990
KIT: IRB-325 (Dist.~ 50 ft)
MX000846
KIT: E3K-R10K4-NR (Dist. ~ 40 ft)
MX000999
NOTE: Bold type indicate sensors or accessories that must be installed together for external entrapment protection to be properly
monitored.
6
D0726 Rev. J
HySecurity Gate Operators
Sensor Type
Wraparound edge
(5 ft for 2" round post)
Edge Interface Module
Wraparound edge
(5 ft for 2" square post)
Edge Interface Module
Edge (3-sided activation
Slide In Style)
(5 ft, 1½" width)
Edge Interface Module
Photo eye, reflective
Wireless Gate Link
Transmitter (battery-
operated, radio control)
Receiver (24VDC, radio
control)
Multi-Input Module
Thru-beam photo eye
Thru-beam photo eye
Photo eye, reflective
UL 325 - 2016 HySecurity Monitored Sensors
Output
Manufacturer
10K Resistor
Miller Edge
Normally Closed
10K Resistor
Miller Edge
Normally Closed
10K Resistor
Miller Edge
Normally Closed
Normally Closed
Miller Edge
Normally Closed
Miller Edge
N/A
Miller Edge
Normally Closed
Normally Closed
Miller Edge
Normally Closed
EMX Industries
Normally Closed
EMX Industries
Normally Closed
Omron
UL 325
Recognized
Type B2
Type B2
Type B2
Type B1
Yes
Yes
Yes
Type B1
Type B1
Type B1