Chapter 5 To Trigger the Oscilloscope

Slope Trigger

In slope trigger, the oscilloscope triggers on the positive slope or negative slope with
the specified time.
Trigger Type:
Press Type, rotate
trigger setting information is displayed at the upper right corner of the screen. For
example,
CH1; the difference between the upper limit of trigger level and the lower limit of
trigger level is 1.24 V.
Source Selection:
Press Source to switch the signal source list between CH1 and CH2. For the details,
please refer to the introduction in "Trigger Source". The current trigger source is
displayed at the upper right corner of the screen.
Note:
Slope Condition:
In this oscilloscope, positive slope time is defined as the time difference between the
two crossing points of trigger level line A and B with the rising edge; negative slope
time is defined as the time difference between the two crossing points of trigger level
line A and B with the falling edge as shown in the figure below.
Press When to select the desired slope condition.
the specified time.
specified time.
MSO2000A/DS2000A User's Guide
nd Quality Products Online at:
to select "Slope" and press down
. The trigger type is slope trigger; the trigger source is
Select channel with signal input as trigger source to obtain stable trigger.
Positive Slope Time
Figure 5-6 Positive Slope Time/Negative Slope Time
: trigger when the positive slope time of the input signal is greater than
: trigger when the positive slope time of the input signal is lower than the
: trigger when the positive slope time of the input signal is greater than
GlobalTestSupply
www.
A
B
Negative Slope Time
. At this point, the