UTILITY PACKAGE (GX Configurator-AD)

5
UTILITY PACKAGE (GX Configurator-AD)
5.1

Utility Package Functions

Table 5.1 shows an overview of the utility package functions.
Item
*1
Initial setting
Auto refresh
*1
setting
Monitor/Test
FB conversion
Table5.1 Utility package (GX Configurator-AD) function list
(1) Sets the following items that require initial setting.
A/D conversion enable/disable setting
Averaging process specification
Average time/Average number of times/Move average/
Time constant settings
Conversion starting time setting (For 2-wire transmitter) (Q66AD-DG)
Warning output settings (Process alarm setting)
Process alarm upper upper limit value/upper lower limit value/
lower upper limit value/lower lower limit value
Warning output settings (Rate alarm setting)
Rate alarm upper limit value/lower limit value
Rate alarm warning detection period
Input signal error detection extended/Input signal error detection set-
ting
Input signal error detection setting value/Input signal error detection
lower limit setting value
Input signal error detection upper limit setting value
Scaling enable/disable setting
Scaling upper limit value/lower limit value
(2) The data for which initial setting has been completed is registered in the
parameters for the programmable controller CPU, and automatically writ-
ten to the A/D converter module when the programmable controller CPU
changes to the RUN status.
(1) Sets auto refresh for the A/D converter module buffer memory.
(2) The buffer memory that was set for auto refresh is automatically read and
written to the specified device when the END command for the program-
mable controller CPU is executed.
(1) Monitor/Test
The buffer memory and I/O signals for the A/D converter modules are
monitored and tested.
(2) Operating condition setting
Changes the initial setting during operation.
(3) Offset/gain setting
When setting the offset/gain to a value selected by the user (when the
analog output range setting is user range setting), the offset and gain can
be easily set while viewing the window.
(4) Pass data
The pass data (industrial shipment settings offset/gain values, user range
settings offset/gain values) can be monitored and set.
Generates FB automatically from the intelligent function module parameter
(initial setting/auto refresh setting).
Description
5.1 Utility Package Functions
1
2
Reference section
3
4
Section 5.4
5
6
Section 5.5
7
Section 5.6
8
Section 5.7
5
- 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q66ad-dgGx configurator-ad (sw2d5c-qadu-e)

Table of Contents