Chapter8 Utility Package (Gx Configurator-Ad/Gx Configurator-Da); Utility Package Functions - Mitsubishi Electric Q64AD2DA User Manual

Analog input/output module
Table of Contents

Advertisement

8
UTILITY PACKAGE (GX Configurator-AD/GX
Configurator-DA)
CHAPTER8
8.1

Utility Package Functions

Table 8.1 lists the functions of the utility package.
Item
(1) The initial values of the following items are set for each channel.
Initial setting
(2) The initial setting data are registered with parameters of the CPU module and automatically
(1) Buffer memory of the Q64AD2DA to be auto-refreshed is set.
Auto refresh setting
(2) Buffer memory of the Q64AD2DA with the auto refresh setting is automatically read and written
(1) Monitor/Test
(2) Maximum value/minimum value information
Monitor/Test
(3) Operating condition setting
(1) An intelligent function module parameter (initial setting/auto refresh setting) is automatically
FB conversion
8
- 1
8.1 Utility Package Functions
UTILITY PACKAGE (GX Configurator-AD/GX
Configurator-DA)
Table 8.1 Function list
(a) A/D conversion area
•A/D conversion/enable disable setting
•Averaging process method setting
•Averaging process (time/number of
times) setting
•A/D conversion scaling enable/disable
setting
•A/D conversion scaling lower limit value
•A/D conversion scaling upper limit value
•Shifting amount to conversion value
(b) D/A conversion area
•D/A conversion enable/disable setting
•D/A conversion scaling enable/disable
setting
written to the Q64AD2DA when the CPU module enters in the RUN status.
to the specified device when the END instruction for the CPU module is executed.
The buffer memory and I/O signals of the Q64AD2DA are monitored and tested.
The maximum/minimum digital output values and the maximum/minimum scaling values are
monitored and reset.
Initial setting items are changed during operation and detection status of input signal error is
monitored.
converted into an FB.
Description
•Input signal error detection setting
•Input signal error detection setting value
•Logging enable/disable setting
•Logging cycle unit setting
•Logging cycle setting value
•Logging data setting
•Logging points after trigger
•Level trigger condition setting
•Trigger data
•Trigger setting value
•D/A conversion scaling lower limit value
•D/A conversion scaling upper limit value
•Shifting amount to input value
Reference
section
Section 8.4
Section 8.5
Section 8.6
Section 8.7