Mitsubishi Electric Q68AD-G User Manual page 72

Channel isolated analog-digital converter module/ channel isolated analog-digital converter module (with signal conditioning function)
Table of Contents

Advertisement

3
SPECIFICATIONS
Address
Hexadecimal
72
H
73
H
74
H
75
H
76
H
77
H
78
H
79
H
7A
H
7B
H
7C
H
7D
H
7E
H
7F
H
80
H
81
H
82
H
83
H
84
H
85
H
86
H
87
H
88
H
89
H
8A
H
8B
H
8C
H
8D
H
8E
H
8F
H
90
H
91
H
92
H
93
H
3.4 Buffer Memory
3
- 47
3.4.1 Buffer memory assignment
Table3.8 Buffer memory assignment of Q68AD-G (4/6)
Decimal
114
CH8 Process alarm lower lower limit value
115
CH8 Process alarm lower upper limit value
116
CH8 Process alarm upper lower limit value
117
CH8 Process alarm upper upper limit value
118
CH1 Rate alarm warning detection period
119
CH2 Rate alarm warning detection period
120
CH3 Rate alarm warning detection period
121
CH4 Rate alarm warning detection period
122
CH5 Rate alarm warning detection period
123
CH6 Rate alarm warning detection period
124
CH7 Rate alarm warning detection period
125
CH8 Rate alarm warning detection period
126
CH1 Rate alarm upper limit value
127
CH1 Rate alarm lower limit value
128
CH2 Rate alarm upper limit value
129
CH2 Rate alarm lower limit value
130
CH3 Rate alarm upper limit value
131
CH3 Rate alarm lower limit value
132
CH4 Rate alarm upper limit value
133
CH4 Rate alarm lower limit value
134
CH5 Rate alarm upper limit value
135
CH5 Rate alarm lower limit value
136
CH6 Rate alarm upper limit value
137
CH6 Rate alarm lower limit value
138
CH7 Rate alarm upper limit value
139
CH7 Rate alarm lower limit value
140
CH8 Rate alarm upper limit value
141
CH8 Rate alarm lower limit value
CH1 Input signal error detection setting value/CH1 Input
142
signal error detection lower limit setting value
CH2 Input signal error detection setting value/CH2 Input
143
signal error detection lower limit setting value
CH3 Input signal error detection setting value/CH3 Input
144
signal error detection lower limit setting value
CH4 Input signal error detection setting value/CH4 Input
145
signal error detection lower limit setting value
CH5 Input signal error detection setting value/CH5 Input
146
signal error detection lower limit setting value
CH6 Input signal error detection setting value/CH6 Input
147
signal error detection lower limit setting value
*1 Indicates whether reading from and writing to a sequence program are enabled.
R : Read enabled
W : Write enabled
*2 When writing data to the buffer memory, always use the interlock condition (buffer memory write
condition) of the following I/O signals.
Buffer memory writing condition
Y9
X9
Writing
Operating
Operating
condition
condition
request
setting
setting
request
completed
flag
*3 Areas used to restore the User range settings offset/gain values when the module is replaced online.
Refer to Chapter 7 for details of online module change.
Description
*1
Default
Reference
R/W
0
*2
R/W
0
*2
R/W
Section 3.4.19
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
Section 3.4.20
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
Section 3.4.21
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
0
*2
R/W
*2
50
R/W
*2
50
R/W
*2
50
R/W
Section 3.4.22
*2
50
R/W
*2
50
R/W
*2
50
R/W
MOV

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q66ad-dgGx configurator-ad (sw2d5c-qadu-e)

Table of Contents