Mitsubishi Electric Q68AD-G User Manual page 250

Channel isolated analog-digital converter module/ channel isolated analog-digital converter module (with signal conditioning function)
Table of Contents

Advertisement

APPENDIX
Device
(S)
System area
(S) + 1
Completion status
(S) + 2
Pass data classification setting
(S) + 3
System area
(S) + 4
CH1 Industrial shipment settings offset value
(S) + 5
CH1 Industrial shipment settings gain value
(S) + 6
CH2 Industrial shipment settings offset value
(S) + 7
CH2 Industrial shipment settings gain value
(S) + 8
CH3 Industrial shipment settings offset value
(S) + 9
CH3 Industrial shipment settings gain value
(S) + 10 CH4 Industrial shipment settings offset value
(S) + 11 CH4 Industrial shipment settings gain value
(S) + 12 CH5 Industrial shipment settings offset value
(S) + 13 CH5 Industrial shipment settings gain value
(S) + 14 CH6 Industrial shipment settings offset value
(S) + 15 CH6 Industrial shipment settings gain value
(S) + 16 CH7 Industrial shipment settings offset value
(S) + 17 CH7 Industrial shipment settings gain value
(S) + 18 CH8 Industrial shipment settings offset value
(S) + 19 CH8 Industrial shipment settings gain value
(S) + 20 CH1 user range settings offset value
(S) + 21 CH1 user range settings gain value
(S) + 22 CH2 user range settings offset value
(S) + 23 CH2 user range settings gain value
(S) + 24 CH3 user range settings offset value
(S) + 25 CH3 user range settings gain value
(S) + 26 CH4 user range settings offset value
(S) + 27 CH4 user range settings gain value
(S) + 28 CH5 user range settings offset value
(S) + 29 CH5 user range settings gain value
(S) + 30 CH6 user range settings offset value
(S) + 31 CH6 user range settings gain value
(S) + 32 CH7 user range settings offset value
(S) + 33 CH7 user range settings gain value
(S) + 34 CH8 user range settings offset value
(S) + 35 CH8 user range settings gain value
App
- 9
Control data of Q68AD-G
Item
Set data
Stores the status when the instruction is
complete.
0
: Normal completion
Other than 0: Abnormal completion
The value set to Pass data classification
setting (S)+2 using the G.OGLOAD instruc-
tion is stored.
0: Voltage specified
1: Current specified
b15
b8 b7 b6 b5 b4
0
0 CH8 CH7 CH6 CH5
CH4 CH3 CH2 CH1
Setting range
0000
to 00FF
H
b3 b2 b1 b0
Set by
System
System
H
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System
System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Q66ad-dgGx configurator-ad (sw2d5c-qadu-e)

Table of Contents