Sensitivity
There are six levels. The sixth level has the highest sensitivity.
Record Channel
The system automatically activates to record selected channels once a motion detection alarm
occurs. Check the box to enable, and the click the buttons for the channels that you want recorded.
The selected channels are highlighted.
Delay
To avoid rerecording the same event, enter the number of seconds to wait after the event has ended
before a new recording can begin. This value ranges from 10s to 300s.
Alarm Out
Check the box to enable the external alarm when the event triggers. In the boxes to the immediate
right, enable which camera(s) will record when the event occurs.
Latch
Select the time in seconds that the system delays after the external alarm has ended before turning
off the alarm and the activated output. This feature sets a postponement period before another
external alarm can be activated. Value ranges from 10 to 300 seconds.
PTZ Activation
This enables you to set PTZ movement when an alarm occurs.
To set PTZ activation:
1. Check the box to enable the function.
2. Click the Setup button. The PTZ Activation dialog appears.
3. Make the desired selections for each channel.