Analog Pattern Gain; Reference Splitting; Serial Com. Baud Rate; Function Test - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

US. 34
Analog pattern
gain
US. 35
Reference
splitting
US. 36
Serial Com.
Baud Rate
US. 37

Function Test

US. 83

Encoder 2

Output PPR

144
The analog pattern can be scaled directly through this parameter. As an example if
the analog signal is +/- 0...5 V, the pattern gain can be changed to 2.00 to provide
full scale control of the motor speed.
Value range: 0.01...20.00
Default setting:
This function creates a slope between two successive speed values which are
transferred serially. This parameter should be adjusted for a time double the actual
serial update rate of the speed command. The function smooths out the relative
course steps which can occur during rapidly changing speed commands.
Value range: 0:Off, 1...200 mSec
Default setting:
This parameter sets the external serial communication baud rate at connector
X6C. This com. port supports the DIN 66019 II standard.
Value range: 0 : 1200 bps
1 : 2400 bps
2 : 4800 bps
3 : 9600 bps
Default setting: 5 : 38400 bps
This parameter allows the user to test certain functions in the drive. They are
described below.
Test Name
Value
None
0 (OFF) default
Fan Test
1
This parameter selects the output PPR for the encoder output channel X3B.
Value range: 0 : 1024 PPR
1 : X3A Input PPR
Default setting: 0 : 1024 PPR
Advanced Parameters
1.00
0:Off
4 : 19200 bps
5 : 38400 bps
6 : 55500 bps
Comments
Turns on all cooling fans such that user
can visually check to see they are running.
Power cycle clears or set back to 0.