Drive Faults - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Diagnostics and Troubleshooting

12.3 Drive Faults

Faults and error, listed alphabetically. Additional troubleshooting of operational problems is listed in Section
12.1 and diagnostics solutions in Section 12.2.
Error/Message Description
bbL
This message
Base Block
precedes most
faults and
indicates the drive
enable (X2A.16)
was removed
while the drive
was outputting
current. This is
not a drive fault.
E.Cdd
The inverter is
Error Calculate
unable to learn
Motor Data
a value during
the Motor Learn
procedure or
during automatic
learn of the
encoder position
during each run.
174
*Additional information at end of section
Cause/Solution/Troubleshoot
Indicates the output transistors have been safely shut off
and are being blocked from further operation.
This generally indicates the drive enable input (I7) was
dropped prematurely or abruptly while the drive was still
outputting current.
This is not a drive error or fault, but a status message.
Verify correct motor data is entered in LF10-17 and re-
try.
Make sure motor contactor is closing.
Make sure motor is wired correctly.
If the problem persists, contact KEB.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents