Parameter Description - Driving Profi le
The run profi le is defi ned by up to seven different speeds and up to three different
sets of accelerations and decelerations. Various combinations of these are
available depending on the mode of control adjusted in parameter LF.2. The
following section describes the adjustment of the speeds and profi les.

Leveling speed, S

L

High speed, S

H

Inspection speed, S

I
Set Speed S
, High
HL
leveling Speed
Leveling speed. The transition to zero speed is always made using
the jerk adjusted in LF.56. this provides a very smooth approach
to the fl oor. Acceleration from zero speed uses profi le 1.
Unit:
feet per minute
Value range:
0...25 ft/min
Default setting:
0 ft/min
Adjustment value:
approx. 4 ft/min
High speed. Acceleration from zero speed and deceleration to
leveling or high leveling uses profi le 0.
Unit:
feet per minute
Value range:
0...LF.20
Default setting:
0 ft/min
Adjusted value:
LF.20 or smaller
Inspection speed. Acceleration and deceleration rates are based
on profi le 1.
Unit:
feet per minute
Value range:
0... 150 ft/min or LF.20 whichever is lower
Default setting:
0 ft/min
Adjusted value:
approx. 35 ft/min
High leveling speed or second inspection speed. Can be used
for short fl oor or one fl oor travel. Acceleration is based on pro-
fi le 1, which can offer independent setting from profi le 0 used in
high speed operation.
Unit:
feet per minute
Value range:
0...LF.20
Default setting:
0 ft/min
Adjusted value:
dependent on use.