Encoder Pulse Number; Encoder Channel Swap / Direction - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Parameter Description - Encoder Set Up

Encoder pulse number

Encoder channel swap /
direction
104
Unit:
Value range:
256...16384 pulse per revolution
Default setting:
Adjustment value:
in accordance with the manufacturer
If the incremental encoder pulse number is not
correctly adjusted, the elevator drive can run very
slowly, or over-speed is possible or other unforeseen
conditions may occur. Therefore, it is absolutely
necessary to adjust this parameter correctly.
This parameter can be used to swap the two encoder channels, reverse
the direction of the entire system, or both swap encoder channel and
reverse the system direction. See also section 5.11.5.
Unit:
Value range:
Default setting:
Adjustment value:
pulse per revolution
1024 pulse per revolution
specifi cations
1
0...3
0
0 nothing reversed
1 encoder change A <--> B swapped
2 motor rotation reversed
3 motor rotation reverse and A<-->B
swapped

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents