Installation and Connection
Drive connection
X3A Female SUBD
15 HD
5
4
3
2
1
10
9
8
7
6
15
14
13
12
11
Max. Load Capacity depending on Voltage Supply
Max. load capacity at +7.5 V:300 mA. The specifi ed current is reduced by the load current taken
from the second encoder interface X3B interface (see section 3.2.6).
HIPERFACE Cable
Pre-manufactured Hiperface cables offer the best solution against noise and disturbance while at
the same time saving installation time. The cables come in standard lengths of 5m,10m,15m,20m,
25m, and 30m.
Cable Part Number
00.S4.809-00xx xx = length in meters, 10 = 10 meters
Mating Connector
00.90.912-003U
Running in Conduit
When this cable must be pulled through metallic conduit, it is necessary to over size the
conduit! Use of a 1 1/2 inch trade size conduit will allow the connectors to pass without removal of
the connectors. Cutting the cable, or removal of the connectors or their housings voids the warranty
and will result in problems with electrical noise after the fact.
Circular connector on
HIPERFACE encoder.
9
8
1
7
2
10
12
6
11
3
5
4
Pin No
Signal Description
1
-
-
2
-
-
3
REF_COS signal input A- (difference signal to COS+)
4
REF_SIN signal input B- (difference signal to SIN+)
5
-
-
6
-
-
7
-
-
8
COS+ signal input A
9
SIN+ signal input B
10
+7.5V Supply voltage for encoder
11
-
-
12
-
-
13
COM
14
-DATA
Data channel RS485
15
+DATA
Data channel RS485
for encoder (solder type)
Encoder pin-out
GND
11
+7.5V
10
REF_SIN
SIN +
DATA -
DATA +
REF_COS
COS +
Shield wire tied to housing
Note: Inner pair shields are tied to 0V (com),
pin 13, not earth ground!
(absolute track for counter and direction detection)
(absolute track for counter and direction
reference potential for supply voltage
X3A pin-out channel 1
4
8
7
6
5
9
detection)
Wire color
13
0V (com)
white
10
+7.5V
brown
4
REF_SIN
red
9
SIN +
blue
14
DATA -
pink
15
DATA +
gray
3
REF_COS
yellow
8
COS +
green
Shield wire tied to housing
which is earth ground.