Inverter Status - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Status Messages

Inverter status

Normal Operating Messages
Display
Signifi cance
No Operation, idle state
noP
Low speed
LS
Forward acceleration
Facc
Forward constant running
Fcon
Forward deceleration
FdEc
Reverse acceleration
rAcc
Reverse constant running
rCon
Reverse deceleration
rdEc
Brake OFF
boff
Brake ON
bon
Calculate drive data
Cdd
Refer to Section 12.1-12.3 for fault codes and trouble shooting.
i
When the drive powers up, the default display is parameter LF.99. This
parameter shows various messages indicating the current operation of
the drive. Each code and its meaning is described below.
Comments
terminal X2.1 (Drive Enable) is not set
drive is enabled but no direction of rotation is
set, motor current still off
Normal run - positioning off
Normal run - positioning off
Normal run - positioning off
Normal run - positioning off
Normal run - positioning off
Normal run - positioning off
Indicates brake should be in the process of
releasing at beginning of run
Indicates brake should be setting at end of run
This message is displayed when the drive is
learning the motor data or encoder position.
131

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents