Recommended Profi Le Settings - KEB COMBIVERT F5 Instruction Manual

Elevator drive
Hide thumbs Also See for COMBIVERT F5:
Table of Contents

Advertisement

Parameter Description - Driving Profi le
Recommended Profi le Settings
These are the recommended profi le settings for standard 6 pole (1165 rpm) motors with geared
machines. For other motors and gearless these values can also be used as a good starting point
however, further adjustment may be required. The minimum jerk value is limited by the rate of
acceleration or deceleration. If it is not possible to adjust the jerk rate lower, it may be necessary
to lower the respective rate of acceleration or deceleration fi rst and then try to lower the jerk.
100
Start Jerk
LF.50 [ft/sec
3
]
Acceleration
LF.51 [ft/sec
2
]
Accel. Jerk
3.25
3
LF.52 [ft/sec
]
Decel. Jerk
3.25
3
LF.53 [ft/sec
]
Deceleration
2
LF.54 [ft/sec
]
F l a r e J e r k
3
LF.55 [ft/sec
]
Stop Jerk
3
LF.56 [ft/sec
]
150
3.0
3.0
2.0
2.5
3.5
3.5
1.8
2.25
2.5
2.5
2.0
2.0
Contract Speed [ft/min]
200
250
3.2
3.1
3.0
3.3
3.75
4.0
3.75
4.0
2.6
3.0
2.5
2.5
2.0
2.0
300
350
3.0
3.0
3.3
3.3
4.0
4.0
4.25
4.5
3.25
3.5
2.5
2.5
2.0
2.0
117