Chapter
6
Scanner Support

IS9CConfig3 Functions

216
The IS9CConfig3 interface provides generic methods for retrieving and
setting configuration using ISCP commands.
ISCP Commands
An ISCP Command is composed of three or more bytes formatted as
<SG><FID><parameters> where:
S SG
Setup group.
S FID
Function ID.
S parameters One or more configuration value bytes depending on the
configuration.
ISCP commands include the following:
Imager Settings
This dictates the start and end column positions for the image dimension.
SG
FID
Parameter
0x7B
80
Value [0..639]
0x7B
81
Value [0..639]
Trigger Settings
This sets the duration of the aiming beam before acquiring images to be
decoded.
SG
FID
Parameter
0x70
81
Value [0..65535]
QRCode Symbology
This enables or disables the QRCode symbology.
SG
FID
Parameter
0x55
40
0
0x55
40
1
Data Matrix Symbology
This enables or disables the Data Matrix symbology.
SG
FID
Parameter
0x54
40
0
0x54
40
1
Description
Start column position.
End column position.
Description
Number of milliseconds.
Description
Disable this symbology.
Enable this symbology.
Description
Disable this symbology.
Enable this symbology.