Syntax
HRESULT IImage::Stop( );
Parameters
None.
Return Values
Status code indicating success or failure as follows:
S S_OK
S S_IMG_NOT_PRESENT_E
S S_DEVICE_NOT_OPENED_E
Remarks
This function stops the image continuously capturing images.
See Also
None.
Syntax
HRESULT IImage::Open( BOOL fSigCapEnable );
Parameters
fSigCapEnable
[in] When TRUE, signature capture is enabled. When
Return Values
Status code indicating success or failure as follows:
S S_OK
S S_IMG_NOT_PRESENT_E
S S_DEVICE_CONTENTION_E
Remarks
This function exclusively allocates the imager device so that the other IIm-
age methods can be safely called.
See Also
None.
Chapter
Imager started.
Unit does not contain an imager.
Device had not been opened.
FALSE, it is disabled. Bar code labels are decoded
and images (via IImage::ReadImage) the same.
Imager opened.
Unit does not contain an imager.
Device has already been opened.
6