4.9.2.3.3.
Beacon of capsule
Enter an information data of Beacon.
1) Serial No.
Enter the serial number of the capsule.
2) Next Replacement
The expiry date of the battery in the beacon of capsule is displayed.
Enter new expiry date of the battery in the beacon, when you exchange the beacon unit.
The expiry date of a battery is indicated on the beacon label.
4.9.2.3.4. Blackout test
Check that the VDR/S-VDR is operated in a blackout.
1) Starting blackout test
Click the [Test Start] button.
Push the [BLACKOUT TEST] switch on the panel of PSU in the RCU for 5 seconds.
A result is displayed on a "Test result" lamp.
2) Result of diagnosis
A result is displayed to the "Test result" lamp.
●
(Green):
Result of diagnosis is good.
●
(Red):
Result of diagnosis is no good.
●
(Orange):
Under a diagnosis
An operation event of AC Power is displayed in the "Status" window.
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
71
4. Installation, Setup and Check
DOC No. 7ZPNA4014