7. Real time Monitor (Menu)
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
7.2.4. Event clear
The monitoring window can be cleared.
Click the [Clear] button.
7.2.5. File save
Monitor data can be saved in the file.
1) Select a saving folder
Click the [Browse] button to select the saving folder.
The saving file name is being fixed to RtMonitor1.txt.
2) Save start
Click the [SAVE START] button.
The sentence data which is monitored can be saved in the text file.
3) Save stop
The [SAVE START] button is changed to the [SAVE STOP] button during the saving.
Click the [SAVE STOP] button.
7.2.6. Quit
1) Monitor stop
Stop all of the channel which is monitoring.
2) Quit
Click the [Close] button.
When the maintenance software is quitted, please make sure that a real –time monitor has stopped
Reboot RCU, when the maintenance software has been quitted without stopping a real-time monitor.
The output of real-time data stops.
DOC No. 7ZPNA4014