14. Program update
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
14.1.2. Select an update program (1. Program)
1) Select a program
Select an update program with a program radio button.
2) Check a version of program
Check a version number of present program.
Click the [Version] button and the version number will appear.
If it is the latest version, program update is not required.
14.1.3. Load a Program file (2. Program File)
Load the update program file.
Click the [Browse] button, and select the update program file.
14.1.4. Check IP address and Port number (3. Port)
It is not necessary input the IP address and the Port number.
Check the entry.
• MCB, ARB:
• RMB:
14.1.5. Update start (4. Update)
Start to update the program.
Click the [Update] button.
State of upload is displayed by progress bar and the message.
14.1.6. Update complete
1) Confirm that the update is completed.
• Check that progress bar is complete till the end.
• Check that" [END] Update Success" is displayed in the progress message
The RCU is restarted automatically and start operation with update program after the upload is complete.
It is not necessary to reset up the system composition information by update.
2) Check the program version which was updated.
Click the [Version] button and the version number will appear.
3) Quit the update application.
DOC No. 7ZPNA4014
192.168.110.3
6000
192.168.60.3
6000
136