4.1.2. Operating procedure for installation
Set up and check the VDR/S-VDR on the "SYSTEM" screen as following procedure.
Step
Item
Receive a system
1
configuration data
2
Set each connection
3
Set a detail information
Transmit a system
4
configuration data to
the RCU
5
Set up the System
6
Reboot the RCU
Check the diagnostic
results
7
Receiving data
Improve, if there is a
8
problem.
9
Recorded data
10
Complete the setup
11
Make the report
The "Report" folder is created on the Desktop of PC automatically.
Compress this folder, and upload the compressed files to the "Ship list" on the Marine service WEB.
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
Operation
Receive button
Check box for connection
Detail button
Set button in each detail
window
Repeat the Step3 and
Step4
Reboot button
Diagnosis button and
lamp
Real time monitor
Return the STEP3
Playback
All diagnostic lamp of
System screen
Report
4. Installation, Setup and Check
Contents
The Maintenance software receives a system
configuration data from the RCU.
Click the [Receive] button.
Setup information is displayed on the System screen
after receiving.
Enter the check mark into the check box of each
connection channel and each configuration unit with
reference to an Installation drawing.
Click the Detail button of the section to set up.
Select the connection channel in sensor section before
clicking the Detail button.
Click the Set button in the detail window after entering
all data.
Enter the detail information data of all section and
each channel of the Sensor section.
Click the Reboot button on the System screen.
The RCU is operated by renewed system configuration
data, after rebooting.
Click the Diagnosis button on the System screen.
Maintenance software shows the diagnostic results by
color of each lamp.
Check the color of diagnostic lamp, green lamp means
OK.
Check a receiving data by the real time monitor.
The red and yellow color of lamp means the problem
of setup, wiring or connection equipments.
Improve the problem shown by the Maintenance
software.
The orange color of lamp means under diagnosis.
Check a recorded data by the Playback software.
Make all lamps green and complete a setup.
A report files are created.
11
See
4.2.1
4.3.1
4.4.1
4.5.1
4.6.1
4.7.1
4.8.1
4.3.2
4.4.2
4.5.2
4.6.2
4.7.2
4.8.2
5
7
10
5
13
DOC No. 7ZPNA4014

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jcy-1850

Table of Contents