4. Installation, Setup and Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.6.3.5. Transmitting setup data
Transmit the setup data to the RCU.
• Transmit
Click the [SET] button.
• Cancel
Click the [Close] button.
4.6.3.6. Result of diagnosis
As for the diagnostic result of the [Radar] section, a result is displayed to the "Diagnosis" lamp.
(Green):
(Red):
(Orange):
* Setting modified data of the "Radar" section becomes effective after the
reboot of RCU.
Therefore, when a setup data is changed, do not refer to the diagnostic result
before rebooting the RCU.
* The diagnostic lamp is displayed also on the SYSYTEM screen.
Click the [Reboot] button on a SYSTEM screen after completing setup, and
check the diagnostic lamp of a SYSTEM screen.
1) FGB
The Ethernet communication link condition of the Frame Grabber Board
(FGB) and the Main Control Board (MCB)
2) Main
The RGB signal from the main radar
3) Sub
The RGB signal from the sub radar
* The diagnostic function needs to be operating.
A "Diagnosis" lamp becomes a blank display when the diagnostic function is not operating.
A diagnostic function can be started with the [Diagnosis] button on "SYSTEM" screen.
DOC No. 7ZPNA4014
Result of diagnosis is good.
Result of diagnosis is no good.
Under a diagnosis
58