  • Page 1

    VOYAGE DATA RECORDER SIMPLIFIED VOYAGE DATA RECORDER INSTALLATION GUIDE 7ZPJD0387C...

  • Page 3

    JCY-1800/1850 VDR/S-VDR Installation Guide RECORD OF REVISIONS Description Date First edition 24-July-06 Second edition (revision: A) 1-Aug-06 Additional item 2.3, 6.2, 9.4, 9.5, etc. Third edition (revision: B) 29-Aug-06 Revised the connection table in the clause 4.2.2. 4th edition (revision: C)

  • Page 4

    JCY-1800/1850 VDR/S-VDR Installation Guide DOC No. 7ZPJD0387C...

  • Page 5

    JCY-1800/1850 VDR/S-VDR Installation Guide SYMBOL MARKS In this manual, and on the product, we use international warning signs to call your attention to important items that, if not handled correctly, could present danger to yourself or property. These warning note classifications are shown below. Understand the meanings of the signs before proceeding to read the manual.

  • Page 6

    JCY-1800/1850 VDR/S-VDR Installation Guide Never short-circuit the + and – pins. Never disassemble, modify, destroy, throw into fire, heat, use with non-specified applications and use after the expiry date. Above acts may cause leakage of fluid, generation of heat, fire, explosion, destruction, or injury by heat.

  • Page 7

    JCY-1800/1850 VDR/S-VDR Installation Guide If water enters into the equipment, turn off the power supply switch, pull out the plug from the outlet, and contact the Sales Department, the nearest branch company, branch office, sales office, or any agent of Japan Radio Co., Ltd.

  • Page 8

    JCY-1800/1850 VDR/S-VDR Installation Guide Do not remove, damage, or alter the labels attached to the equipment. Do not install the equipment, if the location is infringed by water, humid, dusty, or with soot. Ignoring the caution may result in a fire, an electric shock, or a malfunction.

  • Page 9: Table Of Contents

    JCY-1800/1850 VDR/S-VDR Installation Guide TABLE OF CONTENTS SPECIFICATIONS................................1 1.1. Outline of the Equipment ..............................1 1.2. Feature of new VDR/S-VDR............................1 1.3. Difference between VDR and S-VDR...........................4 1.4. JCY-1800 Configuration..............................5 1.5. JCY-1850 Configuration..............................6 1.6. Present and New model Comparison table ........................8 1.7.

  • Page 10: Table Of Contents

    JCY-1800/1850 VDR/S-VDR Installation Guide TROUBLESHOOTING ..............................107 8.1. The Recording Control Unit (NDV-1800/1850)......................107 8.2. The Operation Panel Unit (NCG-169)........................109 8.3. LED Display of LAN Connector..........................113 MAINTENANCE................................115 9.1. Parts list for Maintenance............................115 9.2. How to replace the fans ............................. 116 9.3.

  • Page 11: Specifications

    2) Fixed capsule ▪ Using new VDR capsule produced by L-3 3) Diagnosis of JRC equipment by remote maintenance ▪ Remote maintenance function of JRC equipment is preinstalled. Acquire maintenance data out put from JRC equipment The acquired data can be downloaded.

  • Page 12

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.2.3. S-VDR (JCY-1850) 1) Reception of serial data (NMEA) ▪ Serial reception function is combined to RCU unit. (Combine DAU function) ▪ 16 input channels standard 2) Radar image ▪ Prepare option kit (cable and BNC connector) for FGB connection...

  • Page 13

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.2.6. Operation of inputting two Radar images 1) General description of operation FGB creates PNG files from RGB signals of radar and transmits PNG files via Ethernet. FGB have two input ports for connecting to radar.

  • Page 14: Difference Between Vdr And S-vdr

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.3. Difference between VDR and S-VDR 1.3.1. Main Specifications Item JCY-1800 JCY-1850 Remark Capsule NDH-316 (New capsule is made by NDH-317 (New capsule is made by Only fixed capsule L-3.) L-3.) Main Unit Recording Control Unit (RCU)

  • Page 15: Jcy-1800 Configuration

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 2) Option system Unit S-VDR Remark Waterproof Microphone Unit NVT-162 NVT-162 (Standard) Installed into the NSK interface board CHM-378 7ZZJD0052 Only CH 1 is ( FGB: CKA-137 ,RGB connectable. Frame Grabber Board Kit (Standard)

  • Page 16: Jcy-1850 Configuration

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 2) Options configuration of the equipment Name of Optional Component Type Name Function To use an “Exposed” type, remove the flange of “Built in Microphone Unit NVT-161 the ceiling” one. Maximum nine sets of microphones can be installed, inclusive of standard configuration.

  • Page 17

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide Records the conversation in the bridge and Microphone Unit NVT-161 outputs into the Recording Control Unit. Accessories Spares for the NDV-1850 Spare Parts for RCU 7ZXJD0080 Fans, Fuse for record data playback CF Card adaptor...

  • Page 18: Present And New Model Comparison Table

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.6. Present and New model Comparison table 1.6.1. VDR Item JCY-1700 JCY-1800 Remark Capsule NDH-288A/B (made by L-3) NDH-316 (New capsule is made by Only fixed L-3.) capsule Beacon Beacon Cover: Yes Beacon Water Pressure Sensor: No...

  • Page 19

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.6.2. S-VDR Item JCY-1700S JCY-1850 Remark Capsule NDH-317 (New capsule is made by NDH-317 (New capsule is made by New fixed type L-3.) L-3.) capsule Beacon Beacon Beacon Cover: No Beacon Cover: No Water Pressure Sensor: Yes...

  • Page 20: Jcy-1800 System Diagram

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.7. JCY-1800 System Diagram Figure 1: System Diagram DOC No. 7ZPJD0387C...

  • Page 21: Jcy-1850 System Diagram

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.8. JCY-1850 System Diagram Figure 2: System Diagram DOC No. 7ZPJD0387C...

  • Page 22: Functions Of Electrical Circuit Board

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.9. Functions of electrical circuit board Main electrical circuit table of NDV-1800 (VDR) Unit Model Function S-VDR Remark Circuit name Power supply CBM-168 Battery backup for 2 hours same NBL-327 board (PSB) Thermo sensor...

  • Page 23

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide RCU: NDV-1800/1850 PSU: NBL-327 MCB: CDJ-2304 (ARB: CHA-387) CF Cars CF Cars Audio Interface Board FGB: CKA-137 RMB: CDK-287 Mother Board NIB: CHM-378 NIB: CHM-378 Terminals for serial data BNC connector for RGB Battery...

  • Page 24: Specifications Of Each Unit

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.10. Specifications of each unit 1.10.1. Protective Capsule Unit: PCU (NDH-316) (1) Function: The protective capsule unit (PCU) records navigation data, hull data, conversation in the bridge, conversation over VHF radio, and radar image data to the recording medium in the PCU.

  • Page 25

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.10.2. Protective Capsule Unit: PCU (NDH-317) (1) Function: The Protective Capsule Unit (PCU) is not a float-free type but a fixed type. The PCU records navigation data, hull data, conversation in the bridge, conversation over VHF radio, and radar image data to the recording medium in the PCU.

  • Page 26

    When radar images cannot be recorded, the output data of AIS must be recorded as a substitute. However, JCY-1800/1850 can also record both AIS data and radar images. In case of S-VDR: If the sensor outputs no data by IEC61162, items 5)-12) are not recorded.

  • Page 27

    Radar image data input (input of No1. X band radar is recommended): 1) Input channel: 2 (channels) Auto selection of a radar image from both channels (If the radar is of JRC make, automatic selection of on-operation radar is possible.) 2) Input interface: analog RGB/Hs/Vs - RGB: 0.7Vp-p (video signal)

  • Page 28

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.10.3.3. Power Supply Unit (1) Function: a) Power supply to RCU and PCU in normal operation b) Power supply to RCU and PCU for 2 hours on blackout. (2) Performance: a) Input voltage range:...

  • Page 29

    However, for non-JRC radars, we do not recommend using switching recording function because automatic identification of the working radar is not functional under the normal operation conditions. For using switching recording function in the case of non-JRC radars, read the following specification for proper recording of the working radar images.

  • Page 30

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide CH1 recording mode: Images of CH1 are forced to be recorded. If no images are inputted to CH1, the image data will not be recorded. CH2 recording mode: Images of CH2 are forced to be recorded.

  • Page 31

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.10.5. Microphone Unit (NVT-161) (1) Function: Acquisition of W/H conversation, Alarms and sounds etc. in W/H (2) Performance: a) Type: Ceiling mount type, wall mount type b) Device: Electoret condenser microphone c) Directivity: Hemispherical and omnidirectional d) Receiving range: 2.5m of radius...

  • Page 32

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 1.10.7. Digital Signal Converter (NCT-72) 64CH -Option- The Digital signal converter should acquire alarms or status condition via dry (1) Function: contact closure. (2) Performance: a) Dry contact Input port: Dry (voltage free) contact closure Max.

  • Page 33

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide 2) Current: +/-20mA c) Communication port Same port as dry contact signals d) Data output interface Data type: IEC61162-1 Analog Sentence formatter: XDR (4) Environmental condition: a) Operating temperature: -15°C to +55°C (IEC 60945 protected type) b) Temperature and humidity: +40°C, 93%...

  • Page 34

    1. Specifications JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

  • Page 35: Installation Procedures

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2. INSTALLATION PROCEDURES 2.1. General Installation Procedures 1) Install every unit. 2) Connect the units with cables according to the installation drawing of the ship. 3) Connect cables to the sensors onboard according to the installation drawing of the ship.

  • Page 36: Points Of Installation

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2.2. Points of installation 2.2.1. Capsule 1) Connection box Connection box is wired the same as current box. Power line of capsule is 24 voltages line, and power cable is composed with 2 lines of power line and a shield line.

  • Page 37

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2.2.5. Serial data(NMEA) 1) Wiring It shall be wired the same as previous model (JCY-1700). 2) Reception lamp There is not OK/NG lamp (Green/Red). Reception status is shown on the maintenance software. 3) Operation panel unit Error information of reception is shown by error code on operation panel unit.

  • Page 38

    2.2.7. Switching Radar When two radars are connected and VDR record one of two radar images by switching. 1) In case of JRC Radar The following radars output a PJRC sentence which includes a status of transmitting RF signal. When main radar is transmitting, main radar image is recorded. When main radar is not transmitting, sub radar image is recorded.

  • Page 39

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2.2.8. GPS selection In the following case, GPS selection should be set up. Connecting two GPS units to one port via a switcher Connecting a dry contact signal of switcher 1) Change a recording GPS When the selection information of GPS is connected with a dry contact signal, VDR records change information.

  • Page 40

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 4) System configuration diagram ● Normal system ( XGA or SXGA etc. ) An RGB cable is extended from radar and it connects to VDR. ● Chart radar system with NWP-46 (only UXGA) By connecting NWP-46 to Radar, a LAN cable is extended and it connects to VDR.

  • Page 41: Fgb Kit (7zzjd0052) Installation Procedure

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2.3. FGB Kit (7ZZJD0052) Installation Procedure 2.3.1. Components Parts Type Remark FGB (Frame Grabber Board) CKA-137 Fixed to frame metal RGB cable 7ZCJD0281 D-SUB (15)-BNC (x5) J-J type BNC connector BCJ-JR Fixed to frame metal...

  • Page 42

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide Set the FGB (CKA-137) to the slot. Screw the two screws to fix the FGB. R: Red G: Green B: Blue H: Gray V: Black Connect the RGB cable to the five BNC connectors on the backside of frame.

  • Page 43

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide RGB cable Cable clamp: 2 points Cable clamp: 2 point Cable length is adjusted so that it may not interfere with the door of RCU. Lay the RGB cable. Fix the RGB cable by four cable clamps in the ceiling panel section, and connect with the "RGB1" D-SUB connector of FGB.

  • Page 44

    2. Installation Procedures JCY-1800/1850 VDR/S-VDR Installation Guide 2.3.3. Setup procedure The configuration file for connection Radar unit is uploaded to the FGB. Upload the configuration file with the maintenance software. Refer to the 6.1.7th clause for details. 2.3.4. Check a Radar image Check the recording radar image with the Radar monitoring function of maintenance software.

  • Page 45: Mechanical Installation

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3. MECHANICAL INSTALLATION 3.1. Protective Capsule: NDH-316/317 3.1.1. Selecting the Location The Protective Capsule contains the final recording medium. If the capsule should sink into the sea, it would be retrieved by ROV (Remote Operation Vehicle) or by divers.

  • Page 46

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 2) NDH-317 for S-VDR Mount the capsule with 12 mm steel bolts to the mounting bracket on the external deck. To secure the grounding of the capsule, do not paint the contact surface of the mounting bracket.

  • Page 47

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.1.2.2. Fastening the Capsule Fasten the capsule with external tooth lock washers to the mounting bracket on the external deck. Then, apply a waterproof treatment of RTV (Room Temperature Vulcanizing) sealing material to secure its grounding to the ship’s hull.

  • Page 48

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.1.2.3. Vicinity clearance of the Capsule: NDH-316 / NDH-317 To ease the maintenance of the Protective Capsule and its recovery in the event of any sea accident, make sure that its vicinity is clear and free from obstacles.

  • Page 49: Connection Box: Nqe-3163

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.2. Connection Box: NQE-3163 3.2.1. Selecting the Location The Connection Box connects the Protective Capsule and the Recording Control Unit with a data line and a power supply line. It should be recommended that its location should be selected to meet the following conditions.

  • Page 50

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.2.3. Mounting the Connection Box of VDR (JCY-1800) FIG. 3-2-2: Location for Mounting the Protective Capsule and the Connection Box DOC No. 7ZPJD0387C...

  • Page 51

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.2.4. Mounting the Connection Box of S-VDR (JCY-1850) FIG. 3-2-3: Location for Mounting the Protective Capsule and the Connection Box DOC No. 7ZPJD0387C...

  • Page 52: Recording Control Unit: Ndv-1800 / Ndv-1850

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.3. Recording Control Unit: NDV-1800 / NDV-1850 3.3.1. Selecting the Location It should be recommended that the location for mounting the Recording Control Unit (NDV-1800/1850) be selected to meet the following conditions. It should be recommended that the Recording Control Unit to be mounted in the wheelhouse.

  • Page 53

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 1) NDV-1800 FIG. 3-3-1: Mounting Outline and Vicinity Clearance of the Recording Control Unit NDV-1800 DOC No. 7ZPJD0387C...

  • Page 54

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 1) NDV-1850 FIG. 3-3-2: Mounting Outline and Vicinity Clearance of the Recording Control Unit NDV-1850 DOC No. 7ZPJD0387C...

  • Page 55: Operation Panel Unit: Ncg-169

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.4. Operation Panel Unit: NCG-169 3.4.1. Selecting the Location The Operation Panel Unit should be installed in the bridge console panel or a bulkhead in the wheelhouse. 3.4.1.1. Recommended Location The following is the recommended location for mounting the Operation Panel Unit. It should be in the wheelhouse.

  • Page 56

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide NCG-169 VDR OPERATION PANEL FIG. 3-4-1: Mounting Outline and Vicinity Clearance of the External Alarm Unit (Built-in Type) NC G - 1 6 9 VD R O P E RA T I O N P AN E L...

  • Page 57: Microphone Unit: Nvt-161

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.5. Microphone Unit: NVT-161 3.5.1. Selecting the Location The Microphone Unit collects conversations in the bridge, other voices through the public addressor and the intercom, and alarms buzzers of the group panel installed in the bridge. The locations of the microphones should be carefully selected so that they can record vital voice communications.

  • Page 58

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide FIG. 3-5-1: Mounting Outline and Installation Clearance of the Microphone Unit (Built-in Type) FIG. 3-5-2: Mounting Outline and Installation Clearance of the Microphone Unit (Exposed Type) DOC No. 7ZPJD0387C...

  • Page 59: Waterproof Microphone Unit: Nvt-162 (option)

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.6. Waterproof Microphone Unit: NVT-162 (Option) 3.6.1. Selection of mounting location Waterproof Microphone Units collect conversations about controlling the ship and other voices through the public addressor in the wing. The locations of Waterproof Microphone Units should be carefully selected so that they can collect vital voice communications.

  • Page 60

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide FIG. 3-6-1: Outline of the Waterproof Microphone NVT-162 More than 60 degrees DOC No. 7ZPJD0387C...

  • Page 61: Digital Signal Converter: Nct-72 - 64ch - (vdr Option)

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.7. Digital Signal Converter: NCT-72 - 64ch - (VDR Option) 3.7.1. Selecting the Location The location of a Digital Signal Converter should meet the following conditions. 1) The length of the cable to each sensor should be as sort as possible.

  • Page 62

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide FIG. 3-7-1: Mounting Outline and Vicinity Clearance of a Digital Signal Converter DOC No. 7ZPJD0387C...

  • Page 63: Digital Signal Converter: Nct-63 - 16ch - (vdr Option)

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.8. Digital Signal Converter: NCT-63 - 16ch - (VDR Option) 3.8.1. Selecting the Location The location of a Digital Signal Converter should meet the following conditions. 1) The length of the cable to each sensor should be as sort as possible.

  • Page 64

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide FIG. 3-7-2: Mounting Outline and Vicinity Clearance of a Digital Signal Converter DOC No. 7ZPJD0387C...

  • Page 65: Radar Interface Unit: Nwp-46 (option)

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.9. Radar Interface Unit: NWP-46 (Option) 3.9.1. Selecting the Location The location of a Radar Interface Unit should meet the following conditions. 1) The length of the RGB cable to Radar unit should be as sort as possible.

  • Page 66

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide FIG. 3-9-1: Mounting Outline and Vicinity Clearance of a Radar Interface Unit DOC No. 7ZPJD0387C...

  • Page 67

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3.9.3. Connection to the JMA-900 Chart Radar Unit 3.9.3.1. Fastening the Radar Interface Unit on the JMA-900 Chart Radar Unit Install the Radar Interface unit (NWP-46) as follows procedure. 1)Remove the front cover of Radar Remove the cover of Radar with reference to a “Radar installation guide”.

  • Page 68

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 3) Wiring in the Radar Fix the display cable by the attached clamp. Earth the shield of LAN cable and Power cable to bottom chassis of the Radar. Fix the two cables on the comb type base.

  • Page 69

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide 4)Connect to a Radar Interface unit Connect the power cable to the terminal. Connect the plug of display cable in the “RGB IN” jack. Caution Do not remove this connector when Chart Radar is turned on.

  • Page 70

    3. Mechanical Installation JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

  • Page 71: Cabling

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4. CABLING 4.1. Cabling of the Protective Capsule NDH-316/317 4.1.1. Protective Capsule NDH-316/317 – Connection Box NQE-3163 Two 3m cables are connected to the Protective Capsule NDH-316/317. One is used for power supply, while the other is for data communication; the shielded twist pair cable of Ethernet category-5 based on TIA/EIA-568A standard.

  • Page 72: Cabling Of The Recording Control Unit Ndv-1800/1850

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2. Cabling of the Recording Control Unit NDV-1800/1850 The following cables are connected to the Recording Control Unit (RCU). 1) The power supply cable and the LAN cable of the Ethernet category-5 between the Connection Box and the RCU.

  • Page 73

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.2. Recording Control Unit NDV-1800/1850 – Operation Panel Unit NCG-169 Connect the power supply cable and RS-485 serial cable from the Recording Control Unit to the Operation Panel Unit. The length of each cable should be 30m or less.

  • Page 74

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.4. Recording Control Unit NDV-1800/1850 – Waterproof Microphone Unit NVT-162 The connection table is the same as that of the Microphone Unit NVT-161 except the cable specification. Make sure that the unit number of the Waterproof Microphone Unit coincides with the terminal number of the RCU.

  • Page 75

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Connection table: Video input CH2 RADAR set Signal Name Connector # Connection # Connector panel J106 [R] Red signal J107 [G] Green signal J108 [B] Blue signal Horizontal sync pulse J109 [H] J110 [V]...

  • Page 76

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.6.2. Monitor Timing of the RADAR Video The monitor timing of the RADAR video signal is decided based on the VESA DTMS. The VESA DTMS stands for Video Electronics Standards Association Discrete Monitor Timings Standard.

  • Page 77

    JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.6.3. Connectability of JRC RADAR Series The Connectability of JRC RADAR equipment is tabulated as below. All the RADAR equipment other than JMA-9900 / 9800mk2 needs an additional video buffer inside. 1) JMA-9900 / 9800mk2 series...

  • Page 78

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 3) JMA-900M series (Chart Radar) Resolution 1600 x 1200 pixel Scan Non-interlaced Color Color Output Signal R / G / B / Vs / Hs Connector Vertical Refresh rate 60 Hz Sync Impedance 75 ohms Signal level +5.0 - 0V at 2.2k ohms termination...

  • Page 79

    Positive *To make the output to the VDR viable, please incorporate a VDR connection kit (CFQ-8914, CQD-1891) into the RADAR equipment, using a kit provided by JRC. * JMA-7700 series Radar could be connected to the S-VDR DOC No. 7ZPJD0387C...

  • Page 80

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.7. Recording Control Unit NDV-1800/1850 – Sensor NMEA data The following cables are connected to the Recording Control Unit for recoding NMEA data. • NDV-1800 has 32 ports for inputting NMEA data. • NDV-1850 has 16 ports for inputting NMEA data. (not installed TB404, 405)

  • Page 81

    When radar images cannot be recorded, the output data of AIS must be recorded as an alternative. However, JCY-1800/1850 can also record both all AIS data and radar images. ■ Setup by Maintenance soft ware for recording the AIS data Only by changing the following setup, the data outputted from AIS is recordable by the same setup as other NMEA sentences.

  • Page 82

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.9. Recording Control Unit NDV-1800/1850 – Gyro output the Synchro/Step signal The following cables are connected to the Recording Control Unit for recoding Heading sentence converted from synchro/step signal. 1) Synchro signal Signal Name...

  • Page 83

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.10. Recording Control Unit NDV-1800/1850 – Speed log output the Pulse signal The following cables are connected to the Recording Control Unit for recoding Speed sentence converted from Pulse signal. Pulse signal Signal Name...

  • Page 84

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.12. Recording Control Unit NDV-1800/1850 – External Alarm Lamp Connect the RCU to the External Alarm Lamp, which is incorporated into the External Alarm Console. - Connecting the two lines [A]-[C]: Normal open contact - Connecting the two lines [B]-[C]: Normal close contact Once an alarm is detected in the VDR, the alarm status is displayed.

  • Page 85

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.2.14. Recording Control Unit NDV-1800/1850 – GPS Switch/RADAR Switch When the RCU is connected to either the GPS Switch or the RADAR Switch, it receives dry contact feedback signals from the switch. These signals enable the RCU to display which of the GPS or the RADAR devices is connected to it.

  • Page 86: Cabling Of The Digital Signal Converter Nct-72 / 63 (vdr Option)

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.3. Cabling of the Digital Signal Converter NCT-72 / 63 (VDR option) The following cables are connected to the Digital Signal Converter (DSC). 1) A data cable between Non voltage Digital Signal Converters and the DSC...

  • Page 87

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Connection table for sensors: ch49 ~ ch64 (NCT-72 only) Sensor Signal Name Term # Term # CQD-2081/2012 TB4 [CH-49 to 64] 31/29/27/25/23/21/19/17/15/13 OUT+ Dry Contact Signal: /11/9/7/5/3/1 [IN+] 32/30/28/26/24/22/20/18/16/14 OUT- Dry Contact Signal: /12/10/8/6/4/2 [IN-] [IN-] line is commonly shared by all.

  • Page 88

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.3.3. Digital Signal Converter NCT-72/63 – Recording Control Unit NDV-1800/1850 1) Communication line Connect the serial data line to ch13 through ch16 of the RCU. For each Digital Signal Converter, two way communications port is needed to allow the writing of the setting information or the updating of the software version.

  • Page 89: Cabling Of The Radar Interface Unit Nwp-46 (vdr Option)

    The Radar Interface Unit has two ports for main Radar unit and sub Radar Unit. Prepare connectable cables which should be selected by output connector type of a Radar unit. The RIU is an option unit for connecting the JRC Chart radar (JMA-900M series). Therefore connectable cable to JMA-900M is an accessory of NWP-46.

  • Page 90

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.4.2. Radar Interface Unit NWP-46 – Recording Control Unit NDV-1800/1850 1) Ethernet line Connect the Ethernet line to any VDL-LAN port of the RCU. Connection table: Ethernet line to RCU RIF port RCU port...

  • Page 91: Assembling An Ethernet Connector (rj-45 Type)

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide 4.5. Assembling an Ethernet Connector (RJ-45 type) Assemble an Ethernet connector according to the following procedure. 4.5.1. Assemble outside sheath of an Ethernet cable Cut off outside sheath except for inner LAN Cable at the cable let-in hole.

  • Page 92

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Check by bending the cable that the foil inside is not damaged. If the foil inside is damaged, cut the cable there and go back to the procedure 2 again. Failure example [Failure example] The foil is torn and the core wires inside can be seen.

  • Page 93

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Fold back the foil and roll it up around the cable. The blue surface of the foil must be touched to the sheath. As the same way, fold back the drain wire to attach to the sheath.

  • Page 94

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Untwist the core wires and straighten each wire. After straightening, arrange the core wires so that the wires are aligned in the wiring order. NOTE: Above picture shows the order of “Wiring A.” Wiring A...

  • Page 95

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Insert the core wires into the STP connector. Check that the leading edges of the wires reach to the connector edge. NOTE: Also check that the foil and the drain wire are touched to the metal part inside the connector.

  • Page 96

    4. Cabling JCY-1800/1850 VDR/S-VDR Installation Guide Attach the cable boot. The cable assembling procedure is completed. DOC No. 7ZPJD0387C...

  • Page 97: Instruction

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 5. INSTRUCTION 5.1. Recording Control Unit (NDV-1800 / 1850) 5.1.1. Names of Parts of the Recording Control Unit (NDV-1800 / 1850) 1) Keyhole Figure 5-1: The Recording Control Unit (The front door is closed)

  • Page 98

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide Table 5-1: Names and Functions of the Recording Control Unit Names and Functions Keyhole: Used for opening and closing the front door. Power Supply Unit: Incorporated into the Recording Control Unit. It has an external battery and supplies power to the Protective Capsule Unit, the Operation Panel Unit and the Microphone Unit in case of a blackout.

  • Page 99

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 5.1.2. Power Supply Unit 5.1.2.1. Names and functions of each part of the Power Supply Unit 1) POWER SWITCH 3) POWER LED 8) BATTERY VOLTAGE TEST TERMINAL 7) BLACKOUT 9) FAN TEST SWITCH 2) FUSE 4) BATTERY ABN.

  • Page 100

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide ATTENTION Before turning off the power source, be sure that the CARD LED on the Main Control Board is off. Turning off the POWER SWITCH while the CARD LED is on may result in the physical damage to the CF CARD.

  • Page 101

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 5.1.3. Data Processor Unit 5.1.3.1. Names of each part of the Data processor Unit 9) AUDIO IN CONNECTOR 17) RGB1 IN CONNECTOR 18) RGB2 IN CONNECTOR 7) CF CARD 2) REC START SWITCH 8) CF CARD EJECT BUTTON 12) RMS OP.

  • Page 102

    Lights up when the Remote Maintenance Board can not receive any data. HUB (RMB): The HUB Unit with four switching function. One of the components of JRC-LAN. LAN CONNECTOR (RMB): Connected to the external HUB Unit. RGB1 IN CONNECTOR (FGB): Used as a connector through which the image signals from the main RADAR are input.

  • Page 103

    6) After the copy has been finished, insert the CF CARD into the CARD slot on the Main Control Board. (Be sure that the CF CARD JRC-label side is pointing right.) 7) Make sure that the CARD LED lights up.

  • Page 104

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 5.2. Operation Panel Unit (NCG-169) 5.2.1. Names and functions of each part of the External Operation Board 7) HEADING LED 8) ALARM DETAIL LED HEADING ALARM DETAIL 1) POWER LED 9) MODE SWITCH POWER...

  • Page 105

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide Names and Functions MODE SWITCH: Used to change the operation mode. Press the switch then the operation mode is changed from normal mode to NSK mode or vice versa. In case the heading data is supplied in serial format, NSK mode is not necessary therefore the mode is not changed by the switch.

  • Page 106

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 3. In case of blackout: The ALARM BUZZER sounds in case a power failure happens. Both the POWER LED and ALARM LED blink. The ERROR CODE LEDs blink indicating “10__”. Press the ALARM ACK SWITCH to stop the buzzer. However, during the blackout, unless the ALARM ACK SWITCH is turned on within 2 minutes, the ALARM BUZZER stops automatically.

  • Page 107

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide 5.2.3. How to operate the Operation Panel Unit (on NSK mode) The NSK mode is usable only when the NSK-I/F Board is activated. The board is needed to receive ship’s heading angle either in Synchro or in step mode or to input log speed in pulse. When the NSK-I/F Board is not activated, the Operation Panel Unit is not operated in NSK mode.

  • Page 108

    5. Instruction JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

  • Page 109: Setting

    6. Setting JCY-1800/1850 VDR/S-VDR Installation Guide 6. SETTING 6.1. Recording Control Unit (NDV-1800/1850) setup All setup items are set up with maintenance software. Refer to the instruction manual of maintenance software for setup details 6.2. Digital Signal Converter (NCT-72/63) setup All setup items are set up with maintenance software.

  • Page 110: Analog Signal Converting Board (cef-60) Setup

    6. Setting JCY-1800/1850 VDR/S-VDR Installation Guide 6.3. Analog Signal Converting Board (CEF-60) setup The parameter setup of the following input signal is set up by the strap on PCB. Other setup items are set up with maintenance software. Refer to the instruction manual of maintenance software for details...

  • Page 111: Main Control Board (cdj-2304) /(rmb: Cdk-287) Dip-sw Setting

    6. Setting JCY-1800/1850 VDR/S-VDR Installation Guide 6.4. Main Control Board (CDJ-2304) /(RMB: CDK-287) DIP-SW setting Change a setup of DIP-SW if needed after understanding the purpose of a facility enough. Initial states are all the switches OFF. (The * is marked to the switch which can use in the CDK-287..)

  • Page 112: Frame Grabber Board (cka-129) Strap And Dip-sw Setting

    6. Setting JCY-1800/1850 VDR/S-VDR Installation Guide 6.5. Frame Grabber Board (CKA-129) Strap and DIP-SW setting Factory setting of Strap and DIP-SW are shown below. Do not change the following setting. DOC No. 7ZPJD0387C...

  • Page 113: Error Display

    7. Error Display JCY-1800/1850 VDR/S-VDR Installation Guide 7. ERROR DISPLAY 7.1. Recording Control Unit (NDV-1800/1850) 7.1.1. Power Supply Unit Refer to the 5th clause. Error display of the Power Supply Unit Names and Functions BATTERY ABN. LED: Lights up when the Battery is not ready.

  • Page 114

    7. Error Display JCY-1800/1850 VDR/S-VDR Installation Guide Table 7-1: ERROR code table of the Operation Panel Unit (2/3) ALARM DETAIL CONTENTS CATEGORY SYSYTEM CODE MCB Initialize error An abnormality has been detected in the Main Control Board. CF CARD alarm Ten minutes or more has passed since the CF CARD was taken out.

  • Page 115

    7. Error Display JCY-1800/1850 VDR/S-VDR Installation Guide Table 7-1: ERROR code table of the Operation Panel Unit (3/3) ALARM DETAIL CONTENTS CATEGORY SYSYTEM CODE CH1 Radar image data error The FGB does not receive RGB signals from Radar connected to CH1.

  • Page 116

    7. Error Display JCY-1800/1850 VDR/S-VDR Installation Guide Table 7-2: The conversion table of a code and equipment A connection channel is displayed when the equipment which is not defined by the following table is connected. The codes from 01 to 32 identify connection channel. (S-VDR: 01 to 16)

  • Page 117: Troubleshooting

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide 8. TROUBLESHOOTING If the equipment does not function correctly, check the equipment referring to the list down below. Take the action recommended in the list. If the malfunction still lasts, contact the Sales Department, the nearest branch company, branch office, sales office, or any agent of Japan Radio Co., Ltd.

  • Page 118

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide 8.1.2. Symptom Table for The Data Processor Unit (NDL-46) Symptom Causes Actions to be taken REC LED fails to light. The Recording Control Unit is off. Check the switchboard. The power is not supplied to the Protective Turn on the Power Supply Unit.

  • Page 119

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide 8.2. The Operation Panel Unit (NCG-169) All failures of the Recording Control Unit are indicated by the Operation Panel Unit as an error code. Symptom Causes Actions to be taken All LEDs blink and the The software of the Recording Control Unit lost Reboot the Recording Control Unit.

  • Page 120

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide Symptom Causes Actions to be taken ERROR CODE: “20__” Faulty wiring between the Recording Control Check the Connection Box. lights up. Unit and the Protective Capsule Unit Check the LAN communication by a PING command.

  • Page 121

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide Symptom Causes Actions to be taken ERROR CODE: “33__” GPS is faulty or setting error on the Main Control Check the GPS. lights up. Board If the GPS is error-free, contact us. Check the receiving data and setting data by the Maintenance software.

  • Page 122

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide Symptom Causes Actions to be taken ERROR CODE: “80__” Faulty wiring between the Remote Maintenance Check the wiring between the Remote lights up. Board and the Main Control Board Maintenance Board and the Main Control Board.

  • Page 123: Led Display Of Lan Connector

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide 8.3. LED Display of LAN Connector An LED is incorporated into every LAN connector to display the status. The units equipped with the LAN connector are: HUB Unit on the Main Control Board HUB Unit on the Remote Maintenance Board...

  • Page 124

    8. Troubleshooting JCY-1800/1850 VDR/S-VDR Installation Guide 2) LED Display of the LAN connector of the Frame Grabber Board LINK / SPEED LED (GREEN/ORANGE) ACTIVE LED (YELLOW) FIG. 9-2: LAN C ONNECTOR OF THE RAME RABBER OARD DOC No. 7ZPJD0387C...

  • Page 125: Maintenance

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 9. MAINTENANCE 9.1. Parts list for Maintenance Unit Model Parts Parts code S-VDR ● Recording Control Unit NDV-1800 Mother Board (VDR) CQD-2040 ● /1850 Mother Board (S-VDR) CQD-2057 ● ● Main Control Board CDJ-2304 ●...

  • Page 126: How To Replace The Fans

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 9.2. How to replace the fans If a fan alarm buzzer of the Power Supply unit (NBL-327) sounds, replace the fans with spare ones. 1) Turn off the Power Supply Unit of the Recording Control Unit.

  • Page 127: How To Replace The Battery

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 9.3. How to replace the battery Never short-circuit the + and – pins. Never disassemble, modify, destroy, throw into fire, heat, use with non-specified applications and use after the expiry date. Above acts may cause leakage of fluid, generation of heat, fire, explosion, destruction, or injury by heat.

  • Page 128

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide Thermo-sensor board is attached on the battery. FIG. 9-4: Battery in the Power Supply Unit DOC No. 7ZPJD0387C...

  • Page 129: Checking A Connection Cable In The Rcu

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 9.4. Checking a Connection cable in the RCU These lists show each signals of assembling cable. Refer to these lists for checking a wiring-break. 9.4.1. Cable list Part No. Code Connection Signal Connection numbers Unit Part No.

  • Page 130

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide Part Code Connection list Remark Part Pin No. Signal Part W104 7ZCJD0278 J307 Stop the backup DC J402 Stop: H / Normal: L Blackout detection Blackout: L / Normal: H Stop the un-backup DC...

  • Page 131: Connection Table Of Each Terminals

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 9.5. Connection table of each Terminals Unit Part No. PIN No. Signal Connection data Connection equipment MB (CQD-2040 / 2057) TB406 RX1+ CH1: Serial data receive Sensor Rx1- Rx2+ CH2: Serial data receive Sensor...

  • Page 132

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide Unit Part No. PIN No. Signal Connection data Connection equipment TB401 MB (CQD-2040 / 2057) +24V Capsule Power Capsule NDH-316 / 317 ERR_A Error output by dry contact Alarm board signal (Lamp) ERR_C Power off / Error: AC close...

  • Page 133

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide Unit Part No. PIN No. Signal Connection data Connection equipment MB (CQD-2040) TB404 RX17+ CH17: Serial data receive Sensor Rx17- Rx18+ CH18: Serial data receive Sensor Rx18- Rx19+ CH19: Serial data receive Sensor Rx19-...

  • Page 134

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

  • Page 135: Connection Block Diagrams

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10. CONNECTION BLOCK DIAGRAMS 10.1. System Diagram 10.1.1. VDR JCY-1800 DOC No. 7ZPJD0387C...

  • Page 136

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.1.2. S-VDR JCY-1850 DOC No. 7ZPJD0387C...

  • Page 137: Interconnection Wiring Diagrams

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2. Interconnection Wiring Diagrams 10.2.1. NDV-1800/1850 Recording Control Unit – Page 1 - DOC No. 7ZPJD0387C...

  • Page 138

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.1 NDV-1800/1850 Recording Control Unit – Page 2 - DOC No. 7ZPJD0387C...

  • Page 139

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.1 NDV-1800/1850 Recording Control Unit – Page 3 - DOC No. 7ZPJD0387C...

  • Page 140

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.1 NDV-1800/1850 Recording Control Unit – Page 4 - DOC No. 7ZPJD0387C...

  • Page 141

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.2. NQE-3163 Connection Box DOC No. 7ZPJD0387C...

  • Page 142

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.3. NVT-161 / NVT-162 Microphone Unit / Waterproof Microphone unit MICROPHONE UNIT NVT-161 NVT-162 SPKR TB101 + - s + - 2 3 4 5 MICROPHONE ALLOCATION CONNCTION of NDV-1800/1850 MICROPHONE LOCATION...

  • Page 143

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.4. VHF Line Connection DOC No. 7ZPJD0387C...

  • Page 144

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.5. NCG-169 Operation Panel Unit DOC No. 7ZPJD0387C...

  • Page 145

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.6. NCT-72 Digital Signal Converter – Page 1 - DOC No. 7ZPJD0387C...

  • Page 146

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.6 NCT-72 Digital Signal Converter – Page-2 - DOC No. 7ZPJD0387C...

  • Page 147

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.6 NCT-72 Digital Signal Converter – Page-3 - DOC No. 7ZPJD0387C...

  • Page 148

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.7. NCT-63 Digital Signal Converter – Page 1 - DOC No. 7ZPJD0387C...

  • Page 149

    9. Maintenance JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.7 NCT-63 Digital Signal Converter – Page-2 - DOC No. 7ZPJD0387C...

  • Page 150

    10. Connection Block Diagrams JCY-1800/1850 VDR/S-VDR Installation Guide 10.2.8. NWP-46 Radar Interface Unit DOC No. 7ZPJD0387C...

  • Page 151: Schematic Diagrams (circuit Diagrams)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11. SCHEMATIC DIAGRAMS (CIRCUIT DIAGRAMS) 11.1. NDV-1800 Recording Control Unit of VDR W108 7ZCJD0284 LAN cable W109 7ZCJD0284 LAN cable CF Card (50) J602 J703 J702 J503 J502 VDR-LAN JRC-LAN J504...

  • Page 152: Ndv-1850 Recording Control Unit Of S-vdr

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.2. NDV-1850 Recording Control Unit of S-VDR Option W109 7ZCJD0284 LAN cable CF Card (50) J602 J503 J502 VDR-LAN J504 J408 (64) J406 (90) J409 (10) J306 J308 J307 Thrm. BATT...

  • Page 153: Ncg-169 Operation Panel Unit

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.3. NCG-169 Operation Panel Unit DOC No. 7ZPJD0387C...

  • Page 154: Nvt-161 Microphone Unit

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.4. NVT-161 Microphone Unit DOC No. 7ZPJD0387C...

  • Page 155: Nvt-162 Waterproof Microphone Unit (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.5. NVT-162 Waterproof Microphone Unit (Option) DOC No. 7ZPJD0387C...

  • Page 156: Nct-72 Digital Signal Converter 64ch (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.6. NCT-72 Digital Signal Converter 64CH (Option) DOC No. 7ZPJD0387C...

  • Page 157: Nct-72 Digital Signal Converter 64ch + A/d Option Board (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.7. NCT-72 Digital Signal Converter 64CH + A/D Option Board (Option) DOC No. 7ZPJD0387C...

  • Page 158: Nct-63 Digital Signal Converter 16ch (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.8. NCT-63 Digital Signal Converter 16CH (Option) DOC No. 7ZPJD0387C...

  • Page 159: Nct-63 Digital Signal Converter 16ch + A/d Option Board (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.9. NCT-63 Digital Signal Converter 16CH + A/D Option Board (Option) DOC No. 7ZPJD0387C...

  • Page 160: Nwp-46 Radar Interface Unit (option)

    11. Schematic Diagrams (Circuit Diagrams) JCY-1800/1850 VDR/S-VDR Installation Guide 11.10. NWP-46 Radar Interface Unit (Option) DOC No. 7ZPJD0387C...

  • Page 161: Configuration Of Connection Interface

    12. Configuration of Connection Interface JCY-1800/1850 VDR/S-VDR Installation Guide 12. CONFIGURATION OF CONNECTION INTERFACE 12.1. Ship Identification Information Items Information Remarks Ship’s Name Not yet determined IMO ID Not yet determined 12.2. Ship Specification Information (for reference to installation work)

  • Page 162: List Of Equipment And Connection Interface

    *S-VDR: The “Port No. marked *” should be recorded when the data interface is IEC-61162 standard. When radar images cannot be recorded, the output data of AIS must be recorded as an alternative. JCY-1800/1850 can also record both all AIS data and radar images. Port...

  • Page 163

    12. Configuration of Connection Interface JCY-1800/1850 VDR/S-VDR Installation Guide Port Equipment IEC61162-1/2 Manufacturer Model Serial # Data description Name sentence Not connected ----- ----- ----- ----- ----- Not connected ----- ----- ----- ----- ----- Not connected ----- ----- ----- -----...

  • Page 164

    12. Configuration of Connection Interface JCY-1800/1850 VDR/S-VDR Installation Guide 12.4.2.3. RADAR Signal Contact Interface Equipment Name Manufacturer Model Serial No. Specification Remarks R/G/B/Hs/Vs: BNC connection 1024 x 728 pixels Primary X-band Video: 0.7V peak at 75-ohm X Band RADAR JMA-9823-7XA...

  • Page 165: Recording Data

    Control Unit. However, the information on the initial settings of the system configuration is recorded before the equipment is shipped from a JRC factory or at the time of its installation on the ship. The Recording Control Unit records such signals with time-stamps at an interval of 0.01 seconds.

  • Page 166

    12. Configuration of Connection Interface JCY-1800/1850 VDR/S-VDR Installation Guide For a single frame size, up to 300 kB per 15 seconds. Data are recorded continuously, and when they are overlimited, the old ones are deleted. 12.5.3. Memory Assignment of Each Data Format The Protective Capsule contains a solid state Flash Memory array, which stores data.

  • Page 167: Spare Parts

    13. Spare Parts JCY-1800/1850 VDR/S-VDR Installation Guide 13. SPARE PARTS 13.1. Spare Parts List for the Recording Control Unit NDV-1800/1850 SETS PER SHIP NO. SPARE PARTS LIST FOR VESSEL NDV-1800/1850 RECORDING CONTROL UNIT JCY-1800/1850 VOYAGE DATA RECORDER ITEM NAME OF PART...

  • Page 168: Spare Parts List For The Digital Signal Converter Nct-72/63

    13. Spare Parts JCY-1800/1850 VDR/S-VDR Installation Guide 13.2. Spare Parts List for the Digital Signal Converter NCT-72/63 SETS PER SHIP NO. SPARE PARTS LIST FOR VESSEL NCT-72/63 DIGITAL SIGNAL CONVERTER JCY-1800/1850 VOYAGE DATA RECORDER ITEM NAME OF PART OUTLINE QUANTITY...

  • Page 169: Spare Parts List For The Radar Interface Unit Nwp-46

    13. Spare Parts JCY-1800/1850 VDR/S-VDR Installation Guide 13.3. Spare Parts List for the Radar Interface Unit NWP-46 SETS PER SHIP NO. SPARE PARTS LIST FOR VESSEL NWP-46 RADAR INTERFACE UNIT JCY-1800/1850 VOYAGE DATA RECORDER ITEM NAME OF PART OUTLINE QUANTITY...

  • Page 170

    13. Spare Parts JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

  • Page 171: Maintenance Check List For Vdr/s-vdr

    14. Maintenance Check List JCY-1800/1850 VDR/S-VDR Installation Guide 14. MAINTENANCE CHECK LIST FOR VDR/S-VDR Ship’s Name: Date: Installation Check List for VDR / S-VDR Ship’s Information Ship’s General Information Items Information Remarks Ship’s Name IMO Number Type of Ship Flag State Classification Society Ship’s Propulsion /Rudder System Configuration...

  • Page 172

    14. Maintenance Check List JCY-1800/1850 VDR/S-VDR Installation Guide Records for Inspections For Initial Installation of VDR / S-VDR Inspection Ship’s Name IMO Number Place of Inspection Date of Inspection Inspection Installation /Manuals Ship’s Information (Up-date etc.) General Condition Verification of the VDR/S-VDR functions...

  • Page 185: Annual Inspection

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 15. ANNUAL INSPECTION 15.1. Declaration on completion of annual inspection for VDR DECLARATION ON COMPLETION OF ANNUAL INSPECTION FOR VDR PERFORMANCE TEST Date: Vessel : (Name) IMO Number : This is to certify that the annual inspection for the VDR on board the captioned vessel have been completed satisfactorily as follows.

  • Page 186: Declaration On Completion Of Annual Inspection For S-vdr

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 15.2. Declaration on completion of annual inspection for S-VDR DECLARATION ON COMPLETION OF ANNUAL INSPECTION FOR S-VDR PERFORMANCE TEST Date: Vessel : (Name) IMO Number : This is to certify that the annual inspection for the S-VDR on board the captioned vessel has been completed satisfactorily as follows.

  • Page 187: Annual Inspection Procedures

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 15.3. Annual Inspection Procedures A. Information of Ship and VDR Information of ship and VDR are checked at first. Procedure Check the Ship name, IMO number and ship type. Check the VDR type, serial number, manufactured date, installed date and type approval number.

  • Page 188

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide Check the input voltage. DOC No. 7ZPJD0387C...

  • Page 189

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 2. Functional inspection Procedure & Specification Make sure that on cutting off the power supply from ship’s main, VDR power management shall shift to battery backup mode, which is to supply power source from built-in batteries.

  • Page 190

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 3.2 Sensor data Procedure & Specification Date and time data shall be acquired and recorded. Check that the data is accurately acquired. Check the output equipment and connection interface condition. Ship’s position data shall be acquired and recorded. Check that the data is accurately acquired. Check the output equipment and connection interface condition.

  • Page 191

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide 3.6 Main Alarm data Procedure & Specification Main alarm data on the bridge shall be acquired and recorded. Check that the data is accurately acquired. Main and auxiliary steering gear power unit alarm data shall be acquired and recorded. Check that the data is accurately acquired.

  • Page 192

    15. Annual Inspection JCY-1800/1850 VDR/S-VDR Installation Guide This page is intentionally left blank DOC No. 7ZPJD0387C...

This manual also for:

Jcy-1850

Comments to this Manuals

Symbols: 0
Latest comments: