4. Installation, Setup and Check
JCY-1800/1850 VDR/S-VDR Maintenance Software Instruction Manual
4.5.6.2.3. Calculating a coefficient
Set up the coefficient of the formula this converts the output value (%) of the ACB into a real value (displayed on a
equipment).
1) Selecting CH
Select an analog channel to set up.
2) Setting a minimum value
Operate the analog signal output equipment so that output a minimum value.
• STEP1:
• STEP2:
• STEP3:
2) Setting a maximum value
Operate the analog signal output equipment so that output a maximum value.
• STEP4:
• STEP5:
• STEP6:
3) Checking calculated data
Check the conversion formula is correct.
• STEP7:
• STEP8:
DOC No. 7ZPNA4014
Input the minimum value displayed on the equipment.
Input the A/D conversion value.
Click the [Receive] button. A/D conversion value is inputted automatically.
* Inputting manually is also possible.
Click the [Set] button.
Input the maximum value displayed on the equipment.
Input the A/D conversion value.
Click the [Receive] button. A/D conversion value is inputted automatically.
* Inputting manually is also possible.
Click the [Set] button.
Check that the conversion value on "Check value" and the real value on the equipment are
same.
Click the [Check] button. The conversion value is displayed.
When the conversion value is not correct, redo from STEP1.
Set the coefficient of the formula.
Click the [Apply] button.