Menu 6: Drive Sequencer - Control Techniques Commander SE Advanced User's Manual

Variable speed drive for 3 phase induction motors from 0.25kw to 37kw
Hide thumbs Also See for Commander SE:
Table of Contents

Advertisement

3.6

Menu 6: Drive sequencer

Parameter
6.01
Stop mode selector
6.02
Not used
6.03
AC supply loss mode selector
6.04
Start/stop logic select
6.05
Not used
6.06
Injection braking level
6.07
Injection braking time
6.08
Not used
6.09
Synchronize to a spinning motor
6.10~
Not used
6.11
6.12
Keypad stop key enable
6.13
Keypad fwd/rev key enable
6.14
Not used
6.15
Drive enable
6.16
Electricity cost/kWh
6.17
Power consumption meter reset
6.18~
Not used
6.21
Run time log
6.22
Years/Days
Run time log
6.23
Hours/Minutes
6.24
Power meter MWh
6.25
Power meter kWh
6.26
Running cost
6.27~
Not used
6.28
6.29
Hardware enable
6.30
Digital input control bit 0 (Run/Fwd)
6.31
Digital input control bit 1 (Jog)
6.32
Digital input control bit 2 (Run/Rev)
6.33
Digital input control bit 3 (Fwd/Rev)
6.34
Digital input control bit 4 (Run)
6.35~
Not used
6.38
6.39
Digital input control bit 5 (Not Stop)
6.40
Enable latching run inputs
6.41
Control word mask
6.42
Control word
6.43
Control word enable
Commander SE Advanced User Guide
Issue Number: 4
Range
Type
0~4
RW
Uni
0~2
RW
Uni
0 ~ 4
RW
Uni
0 ~ Active
RW
Uni
current limit
0.0 ~ 25.0 secs
RW
Uni
0 ~ 3
RW
Uni
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0.0 ~ 600.0
RW
Uni
0 or 1
RW
Bit
0 ~ 9.364
RO
Uni
Years.Days
0 ~ 23.59
RO
Uni
Hours.Minutes
0.0 ~ 999.9 Mwh
RO
Uni
0.0 ~ 99.99 kWh
RO
Uni
0 ~ 32000
RO
Uni
Currency/Hour
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
0 or 1
RW
Bit
RW
Uni
RW
Uni
0 or 1
RW
Bit
Default
1
0
R
0
100
1.0
0
(EUR) 0
(USA) 1
0
1
0
0
S
P
S
P
S
P
S
P
P
0
0
0
0
0
0
0
0
0
0
0
Update
Setting
Rate
L1
L2
B, I
B
L1
B
B
L1
L1
B
B
B
B
B
B
B
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
L1
51

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents