Quickey Compatibility; Controlling The Commander Se Via The Universal Keypad - Control Techniques Commander SE Advanced User's Manual

Variable speed drive for 3 phase induction motors from 0.25kw to 37kw
Hide thumbs Also See for Commander SE:
Table of Contents

Advertisement

12.25

Quickey Compatibility

Due to different versions of Drive user interface software, it is possible to get a compatibility issue when using the Quickey to
clone parameter set-ups between drives. This compatibility issue will cause the drive to trip on C.dat.
The following table gives the compatibility between different versions of drive user interface software:
Software
V01.02.01
V01.03.00
V01.05.00
V01.07.00
V01.08.00
V01.09.01
V01.10.00
V02.00.01
V02.00.04*
NO:
The Quickey cannot clone between these two versions of drive software
YES:
The Quickey can clone between these two versions of drive software
*V02.00.04 is only used on Commander SE Size 5.
12.26

Controlling the Commander SE via the Universal Keypad

Example 1
This set up uses the UP and DOWN buttons on the Universal Keypad to control the speed of the motor: UP to increase the
speed and DOWN to decrease the speed.
The Enable/Stop/Start/Forward/Reverse control is from the drives terminals and not the Universal Keypad buttons.
Keypad top line display set up
Parameter
99.16
99.17
99.20
99.41
99.42
99.43
Keypad bottom line display set up
Parameter
99.09
99.10
99.13
Keypad buttons set up
Parameter
99.05
Drive parameters set up
Parameter
00.05
6.43
Perform a save routine: xx.00 = 1000 and press the red Stop / Reset button on the drive.
Perform a Universal Keypad save routine: 99.00 = 1000 and press the red Stop / Reset button on the keypad.
Commander SE Advanced User Guide
Issue Number: 4
V01.02.01 V01.03.00 V01.05.00 V01.07.00 V01.08.00 V01.09.01 V01.10.00 V02.00.01 V02.00.04*
NO
NO
NO
YES
NO
YES
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Description
HMI 2 source address
HMI 2 source parameter
HMI 2 text
HMI 2 increment
HMI 2 upper limit
HMI 2 lower limit
Description
HMI 1 source address
HMI 1 source parameter
HMI 1 text
Description
Keypad control buttons
Description
Speed reference selector
Control word enable
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
Value
11
1.21
Speed reference
100
50,000
0
Value
11
4.01
Motor I
Value
Disable
Value
Pr
0
NO
NO
NO
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
187