Destination AUD parameters can be configured from this panel. See section on
configuration via panels for details.
16 assignable overrides and no keyswitch input or 15 assignable overrides plus
keyswitch input are supported
.
Overrides can operate on any source on any level.
Type 5, dual 8 character destination follow UMD
This panel type actually assigns a dual 8 character destination follow UMD to a
panel position on a chain. The UMD will only be capable of destination follow. The
dual 8 character UMD can be used to follow either a single destination or two
destinations.
When being used to follow a single destination the last eight characters of the
UMD are used to display the source routed. The display message is still 16
characters long but the first 8 characters are spaces.
When being used in dual mode the first 8 characters (LHS of display) are used to
display the source routed to the first destination assigned and the second 8
characters (RHS of display) are used to display the second destination assigned.
If only one destination association is assigned to the UMD then the UMD assumes
single destination follow.
The source name displayed is for the source routed to the destination of the first
level assigned in the destination association.
When display AUD parameters is enabled for the UMD then the eighth character
of the display is used to indicate the combined source and destination audio
parameter for the most significant active Analogue Audio level configured. The
source name is limited to the first 7 characters. See Panels with displays section
for definition of symbols used.
To assign destination associations to the UMD a destination keypad must first be
set up using the 'KD' command and then assigned to the UMD using the 'PT'
command. The 'PT' command also assigns the UMD to a panel position on a chain
.
Type 6, 16 character destination follow UMD
This panel type actually
assigns
a 16 character destination follow UMD to a panel
position on a chain. The UMD will only be capable of single destination follow.
These UMDS use the middle 8 characters (characters 4 to 12) to display the source
name
.