There are no communications using RS232-1 ?
•
check the power
•
check that the associated LED on the
Freeway
control card is flashing
indicating valid data received from the controller
•
check that the controlling device is connected to the RS232-1 port on the
Master router
•
check cable interconnections
•
check electrical characteristics and protocol of controlling device are
compatible with that configured into the
Freeway
database
There is no communication with external controllers on
RS485 ports?
•
check power
•
ensure
Freeway
control card is running - LED 4 flashes
•
check that the 2440
Freeway
control card is configured for controller mode
operation
•
check cable interconnections
•
check that the associated LED on the
Freeway
control card is flashing
indicating valid data received from the controller
•
check electrical characteristics and protocol of controlling device are
compatible with that configured into the
Freeway
database
There is no communication with panels on RS485 ports
panels in self-test?
•
check power
•
ensure
Freeway
control card is running - LED 4 flashes
•
check that the 2440
Freeway
control card is configured for peripheral mode
operation
•
check cable interconnections