Controller Configuration - pro bel Freeway Manual

Table of Contents

Advertisement

Freeway Ra nge
Pro-Bel ltd
• 4.3 Controller configuration
The controller has provision for configuration. There exists an editor port, and an
8-way piano key switch to support a configurable system.
Editor port
This is an RS232 port connected to a simple PC based editor. (See Salvos section
for more details.)
Configurable switches
The function of each of the switches located on the 2440 are defined in the table
below.
Switch
Function
Selection
Default
UP
DOWN
1
MASTER/SLAVE SELECT
SLAVE
MASTER
DOWN
2
I-lP CLOCK SELECT
10 MHz
20 MHz
DOWN
3
SYSTEM RUN MODE
NORMAL
TEST
UP
4
RS232 PORT SELECT
EDITOR
REMOTE
UP
5
DEFAULT TRIGGER
SELECT
625
525
UP
6
RE-CONFIGURE
MANUAL
AUTO
UP
7
DATABASE TYPE
FIXED
CONFIGURE
UP
8
CONTROL MODE
GENERAL
PANELS
UP
A description of the function of each of the switches is given
below:
sw2_1 Master/Slave select is used
,
in dual control situations, to assign
Master/Slave status to the 2440 control cards. One card would be set to MASTER
and the other to SLAVE so that on reset or power up the Master 2440 powers up
first and, hence, always becomes the active controller.
6540T-00 Nov 97