pro bel Freeway Manual page 100

Table of Contents

Advertisement

Freeway Range
Pro-Bel
ltd
3
=
General Remote Control
(SW-P-08)
4
OEM protocol
baud
:
3
=
300
12
=
1200
24
2400
48
4800
96
9600
19
19
200
38
38400
57
57600
11
115200
23
230400
data:
7 or 8 bits (NB
Pro-Bel
protocols always require 8
bits)
parity:
E
EVEN
o
ODD
N
NONE
stop:
lor2bits
RS232 hs:
ON
=
RTSjCTS flow control enabled
OFF
=
RTSjCTS flow control disabled
duplex:
F
=
Full duplex (4-wire)
H
Half duplex
(2-wire)
inhibit
:
y
This port will take note of internal route inhibit
table
N
This port ignores internal route inhibit table
Changes to the RS485 General Remote ports are effected immediately if Database
mode is in
CONFIGURE.
Changes
to the RS
23 2 General
Remote port are stored in the editable database and
only take effect when the RS232 port is switched to be a General Remote port. the
Database mode is in CONFIGURE and the controller is RESET.
Note
1.
The RS232 General Remote port does not support multi-drop
communications protocol or high baud rates
;
230400,115200,57600.
Note 2. The RS485 General Remote ports ignore the
RS23 2
hs parameter in
message.
6540T-00 Nov 97