pro bel Freeway Manual page 80

Table of Contents

Advertisement

Freeway Range
Pro-Bel ltd
If more than one button is assigned as <ALT-LEV> then all these buttons will have
there lamps updated together.
Panel lock via a keyswitch input is not supported on Type 2 panels.
If line-up is initiated from another panel then tally indications on Type 2 panels
will be updated accordingly.
These types of panels have a source and destination keypad associated with a
different group of buttons on the panel. Any source association can be assigned to
a <SOURCE> button on the assigned button per source keypad and any destination
association can be assigned to a <DESTINATION> button on the assigned button
per destination keypad.
A destination association is selected by pressing the required <destination>
button. The destination button will illuminate along with the source button
corresponding to the source routed for the destination on the most significant
level. If the current source routed is assigned to more than one source button then
the tally indicated will be either the tally for the last source button pressed or the
first button that source is assigned to.
Crosspoints are set by pressing the appropriate <SOURCE> buttons - the current
tally indicated by an illuminated source button LED
.
Crosspoints are only set on the controllable, active levels.
The PROTECT feature can be assigned to any button on the panel by assigning
the protect association to a button position on the button per source keypad or
the button per destination keypad. More than one button can be assigned as a
<PROTECT> button.
There are no override inputs associated with this type of panel.
Type 3, 6276 X-V
This type of panel provides
X-Y
control of all source and destination associations
with breakaway on all eight controllable levels. Tally indications use 8 character
names. This panel also has a keyswitch input to disable the <TAKE>
button.
This panel type uses the main 8x4 keypad for pre-selecting source and destination
associations. The source and destination keypad is overlaid on top of each other.
Any source or destination association button selection sequence can be assigned
to any of the 32 source or destination buttons.
Either the button per source/destination keypads or the 8 character display dial­
up keypads can be assigned to this type of panel. If the button per source or
6540T-00 Nov 97
80

Advertisement

Table of Contents
loading

Table of Contents