The panel is communicating but no (or incorrect) responses
to button presses - panels not in self-test?
check cable interconnections
ensure that each panel has a unique serial address
check that the panel is configured for multi-drop operation
The panel controls wrong destination?
check that the panel is assigned correctly in database
The panel cannot select a crosspoint?
check
database
for:
panel assignment
level active
route not inhibited
no override active
level controllable
check level and sub-level switches
check system has detected modules on level by using 1M command on
PC/terminal
The panel selects crosspoint but signal routed is absent or
low quality?
check router cards are properly seated
ensure ribbon cables on front edge of cards are plugged in correctly
check cables are properly connected on rear panels
ensure rear panels are properly installed
Cannot select crosspoint from external controllers?
check database for
:
route not inhibited
no override active
check level and sub-level switches
check system has detected modules on level