pro bel Freeway Manual page 79

Table of Contents

Advertisement

Pro-Bel
ltd
Technical manual
To unprotect a destination: select the desired <OEST> button «PROTECT> button
lamp lit if any level of the selected destination association is protected from this
panel); activate required levels
;
press <PROTECT> button. The destinations are
now unprotected. If all destinations have been unprotected by this action then the
<PROTECT> button lamp will be extinguished.
The <PROTECT> button lamp indication will be for the most significant active
controllable level for the destination association selected.
A protect lamp ON indicates that the most significant active controllable level in
the selected destination association is protected from this panel.
A
protect
lamp ON for a period of 5 seconds. after a take, indicates that at least
one active controllable level in the selected destination association is protected.
A protect lamp OFF indicates that the most significant active controllable level in
the selected destination association is unprotected.
A protect lamp FLASHing indicates that the most significant active controllable
level in the selected destination association is protected from another panel.
Protects can only be removed by
:
the original panel that set them (see description above)
a Master
X-Y
panel
Buttons on either source or destination keypads can be assigned as
<PROTECT>.
If more than one button is assigned as a protect then only the first <PROTECT>
found will have its lamp updated.
The levels controllable can be assigned to Type 2 panels via Editors.
Salvos are not destination association oriented. Selecting a <SALVO> button causes
all routes set up in that salvo to be made if they are not inhibited or protected.
Salvo takes ignore status of any <PROTECT> buttons on the panel.
The <SALVO> button lamp is either lit for 5 seconds (indicates no error in salvo
take) or flashes for 5 seconds ( indicates error in salvo take) before returning to
the correct tally
.
This 5 second period can be overridden if a <SOURCE>, <SALVO>,
or <PROTECT> button is pressed in this time
.
In each instance the <SALVO> button
lamp is extinguished and the correct tally indication is restored.
Selecting the same salvo from another panel does not cause an update of this
panel's <SALVO> button lamp.
6540T-OO Nov 97
79

Advertisement

Table of Contents
loading