[Sysname-GigabitEthernet1/0/1] quit
# Add the event entries numbered 1 and 2 to the event table, which will be triggered by the following
extended alarm.
[Sysname] rmon event 1 log
[Sysname] rmon event 2 trap 10.21.30.55
# Add an entry numbered 2 to the extended alarm table to allow the system to calculate the alarm
variables with the (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) formula to get the numbers of all
the oversize and undersize packets received by GigabitEthernet 1/0/1 that are in correct data format
and sample it in every 10 seconds. When the change ratio between samples reaches the rising
threshold of 50, event 1 is triggered; when the change ratio drops under the falling threshold, event 2 is
triggered.
[Sysname] rmon prialarm 2 (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1) test 10
changeratio rising_threshold 50 1 falling_threshold 5 2 entrytype forever owner user1
# Display the RMON extended alarm entry numbered 2.
[Sysname] display rmon prialarm 2
Prialarm table 2 owned by user1 is VALID.
Samples type
Variable formula : (.1.3.6.1.2.1.16.1.1.1.9.1+.1.3.6.1.2.1.16.1.1.1.10.1)
Description
Sampling interval
Rising threshold
Falling threshold
When startup enables
This entry will exist : forever.
Latest value
: changeratio
: test
: 10(sec)
: 100(linked with event 1)
: 10(linked with event 2)
: risingOrFallingAlarm
: 0