1.
Enter the schedule number (01-20) and time
window number (01-20), and note the day of the
week the action is desired.
2.
Enter the code for the desired action and
action specifier. The action codes represent the
events that are to take place when the scheduled
time is reached. Each action also requires an
action specifier, which defines what the action will
affect (relay, relay group, partition, zone list, user
group). The action specifier varies, depending on
the type of action selected.
The following is a list of the Action Codes (desired
actions) used when programming Time-Driven events.
Note that these codes are independent of the relay
codes programmed during Output Programming in the
#93 Menu Mode.
Relay Commands
Action Code
Action
01
Relay On
02
Relay Off
03
Relay Close for 2 seconds
Relay Close XX minutes (set
04
in field 1*74)
Relay Close YY seconds (set
05
in field 1*75)
06
Relay Group On
07
Relay Group Off
Relay Group Close for 2
08
seconds
Relay Group Close XX
09
minutes (set in field 1*74)
Relay Group Close YY
10
seconds (set in field 1*75)
Arm/Disarm Commands
Action Code
Action
20
Arm-STAY
21
Arm AWAY
22
Disarm
Force Arm STAY (Auto-
23
bypass faulted zns)
Force Arm AWAY (Auto-
24
bypass faulted zns)
25
Arm INSTANT
26
Arm MAXIMUM
The auto-arm warning (field 2*06) applies
when using Time-Driven events to auto-arm.
Temporary schedules do not override an
auto-arming or auto-disarming programmed
in Time-Driven events.
The auto-arming window cannot be extended
using the Installer Code + #82 Mode.
Bypass Commands
Action Code
Action
30
Auto bypass – Zone list
31
Auto unbypass – Zone list
6-8
Open/Close Windows
Action Code
40
41
42
50
Access Control Commands 55-78 Not Used
3.
Activation
Action Specifier
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Action Specifier
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Action Specifier
Zone list #
Zone list #
Action
Enable Opening Window by
partition
Enable Closing Window by
partition
Enable Access Window for
access group
Off-Normal Reminder
(starts local keypad beeping if
fire or system trouble
condition exists)
Enter the desired activation time (when the
action is to take place). Select from:
Description
Time
1
Beginning of time window.
2
End of time window.
3
During time window active period only (on at
beginning of window, off at end).
For example, if bypass is selected to activate during
the window, zones in a zone list are bypassed at the
beginning of the window and unbypassed at the end
of the window.
4
Beginning and end of time window (e.g., a coffee
break buzzer). In this example, if relay pulse is
selected, the relay pulses for 2 seconds at the
beginning of the window, signaling the beginning of
the coffee break. At the end of the window it pulses
again, signaling the end of coffee break.
5
Random time at the start of the time window (occurs
within 30 minutes after the start of the time window).
NOTE:
Since the randomization for choice "5"
occurs within 30 minutes after the start of the
window, the time window duration must be at least
30 minutes.
6
Random time at the end of the time window (occurs
within 30 minutes after the end of the time window).
7
Random during the time window (begins within 30
minutes after the start of the time window and ends
within 30 minutes after the end of the time window).
NOTE:
Since the randomization for choice "7"
occurs within 30 minutes after the start of the
window, the time window duration must be at least
30 minutes.
Action Specifier
Partition(s)
Partition(s)
Access Group
None

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-128fbpVista-250fbp

Table of Contents