VISTA-128FBPN Installation and Setup Guide
A response type 19 (24-Hour Trouble) must be programmed for zones 990 (1
U L
UL installations.
The 5881ENHC receiver contains front and back tampers that permit its use in commercial burglary installations.
You may only mount the 5881ENHC its own plastic housing. Otherwise, the receiver constantly reports a tamper
condition.
The control checks the receiver connections about every 20 seconds. The receiver supervisory zone is 8 + 2-digit
receiver device address (for example, Device address 05 = supervisory zone 805).
NOTE: This zone must be programmed with a response type (e.g., type 19 24-Hour Trouble) before it supervises the
connection to the receiver.
Use two identical receivers to provide either a greater area of coverage or redundant protection. They must be set for
different addresses.
Any zone from 1 to 128 can be used as a 5800 Series wireless zone, with the exception of zone 64 (reserved for a
wireless keypad).
RF System Installation Advisories
Place the receiver in a high, centrally located area. Do not place it on or near metal objects. This will decrease the
range and/or block transmissions.
Install the RF receiver at least 10 feet from the control panel or any keypads, to avoid interference from the
microprocessors in these units.
If dual receivers are used:
a.
Both must be at least 10 feet from each other, as well as from the control panel and remote keypads.
b.
Each receiver must be set to a different device address. The receiver set to the lower address is considered the
st
1
RF receiver for supervisory purposes.
c.
The House IDs must be the same.
d. Using two receivers does not increase the number of transmitters the system can support (127 zones
using the 5881ENHC or 5883H).
Installation and Setup of the 5881/5883 RF Receivers
Take note of the address you select for the RF receiver, as this address must be enabled in the system's Device
Programming in the #93 Menu Mode.
To install the 5881ENHC/5883 RF receiver, perform the following steps:
Step
Action
1
Mount the receiver, following the advisories stated previously.
NOTE: Must be mounted in a 5800Box Enclosure.
2
Set the DIP switches in the receiver for the address (01-07). See Figure 3-19.
Make sure the address setting is not being used by another device (keypad, relay module, etc.).
3
If installing a 5881ENHC, install a flat-head screw (supplied) in the case tamper tab as shown in Figure 3-
18. When the receiver is pried from the wall, the tamper tab will break off and remain on the wall. This will
activate a tamper switch in the receiver and cause generation of a tamper signal. Note that this signal will
also be generated when the receiver's front cover is removed.
4
Connect the receiver's wire harness to the keypad terminals (11, 12, 13 and 14). Plug the connector at the
other end of the harness into the receiver.
5
Refer to the Installation Instructions provided with the receiver for installations regarding antenna