VISTA-128FBPN Installation and Setup Guide
The partition-specific programming fields are
automatically skipped when programming the
global fields. If the system has only 1 partition,
the partition-specific fields are not automatically
skipped.
To program system-wide data fields, perform the
following steps:
Step
Action
1
Enter Program Mode: Installer Code + 8 0 0 0.
The following display appears:
Program Mode
✳Fill # View – 00
2
If the control has not been programmed before,
enter ✳97 to load factory defaults.
3
Press [✳] and enter the first field number to be
programmed (for example, ✳00, Installers
Code). Make the desired entry. When the field
is complete, the keypad beeps three times and
advances to the next field. If you do not want to
change the next field, press [✳] and enter the
next field number to be programmed.
First Page of fields
(✳00 - ✳90)
To move to the next page of fields, press ✳94.
To return to the previous page, press ✳99.
Press ✳99 or ✳98 to exit Program Mode.
4

#93 Menu Mode Programming

The #93 Menu Mode is an interactive mode through
which much of the system's programming is done. In
this mode, there are "question and answer" prompts
that can be accessed once Data Field Program Mode has
been entered. These prompts require a 2-line alpha
keypad (6160/6160CR-2).
4-2
NOTE: If the number of digits that you enter in a data
field is fewer than the maximum permitted (for
example, a phone number), the keypad displays the last
entry and waits. To proceed, enter [✳] + the next data
field you wish to program.
Programming Partition-Specific Data Fields
To program partition-specific data fields once in
Program Mode, do the following:
Step
Action
1
Enter Program Mode: Installer Code + 8 0 0
0.
Press ✳91, which will prompt you for the
2
partition number desired.
3
Enter a partition-specific field number (e.g.,
✳09) to begin programming.
When the first field's entry is completed, the
next partition-specific field is automatically
displayed. When all partition-specific fields
are programmed, the system returns to the
global programming fields (page 1 fields).
4
Repeat this procedure for each partition in
the installation.
NOTE: To return to the global program fields before
finishing all fields, enter any global field number.
Programming Partition-Specific Fields
Press ✳91 to select a partition.
Enter the partition to be programmed.
Enter a partition-specific field number and make entry.
After partition-specific fields are programmed,
press ✳91 to select next partition.
Enter any global field number to return to the global
fields at any time.
After programming all system-related programming
fields in the usual way, press #93 while still in
programming mode to display the first choice of the
menu-driven programming functions. Press 0 (NO) or 1
(YES) in response to the displayed menu selection.
Pressing 0 will display the next choice in sequence.
↓ ↓ ↓ ↓
↓ ↓ ↓ ↓
↓ ↓ ↓ ↓