5. CiA 402 DRIVE PROFILE
7) Method 23 and Method 27 (Homing on home switch and index pulse)
The following figure shows the operation of Homing method 23. The operation direction of
Homing method 27 is opposite to that of Homing method 23.
Statusword bit 10
ON
Target reached
OFF
Statusword bit 12
ON
Homing attained
OFF
Forward
rotation
Servo motor speed
0 r/min
Reverse
rotation
ON
DOG (Proximity dog)
OFF
Controlword bit 4
ON
Homing operation start
OFF
Servo motor speed
Servo motor speed
Note.
The software limit cannot be used with these functions.
Home position
Acceleration time
return speed
constant
Home position return position data
3 ms or shorter
Home position
return direction
0 r/min
Reverse
rotation
After retracting to before proximity dog,
the home position return starts from here.
When a home position return is started from the proximity dog
Home position
return direction
Forward
Home position return start position
rotation
0 r/min
Reverse
rotation
The home position return starts from here.
When the movement is returned at the stroke end
Deceleration time constant
Creep speed
Proximity dog
Home position return start position
Proximity dog
5 - 40
Travel distance after proximity dog
+
Home position shift distance
Proximity dog
Stroke limit (Note)