SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
0-0 Help Comments
DTC
FAULT MESSAGE
009 DRIVE PREVENTED - ELEVATED ABOVE
DRIVE CUTOUT HEIGHT

2-1 Power-Up

DTC
FAULT MESSAGE
211 POWER CYCLE
212 KEYSWITCH FAULTY

2-2 Platform Controls

DTC
FAULT MESSAGE
221 FUNCTION PROBLEM - HORN PERMA-
NENTLY SELECTED
222 FUNCTION PROBLEM - INDOOR / OUT-
DOOR PERMANENTLY SELECTED
6-14
DESCRIPTION
The platform is elevated above the cali-
brated cutout height.
DESCRIPTION
This help message is issued at each power
cycle. Displays on the analyzer only.
Both platform and ground modes are
selected simultaneously. Defaults to
ground mode.
DESCRIPTION
The horn switch was closed during power-
up in platform mode.
The indoor / outdoor (zone A / zone B)
switch was closed during power-up in plat-
form mode.
– JLG Lift –
CHECK
• Check that the elevation angle sensor is securely mounted.
Refer problem to a qualified JLG mechanic.
CHECK
Normal operation. No check necessary.
Refer problem to a qualified JLG mechanic.
CHECK
• Check if the horn switch is damaged, obstructed or jammed.
Refer problem to a qualified JLG mechanic.
• Check if the indoor/outdoor (zone A / zone B) capacity switch is damaged,
obstructed or jammed.
Refer problem to a qualified JLG mechanic.