6-7 Accessory
DTC
FAULT MESSAGE
671 ACCESSORY FAULT
7-7 Electric Motor
DTC
FAULT MESSAGE
771 OPEN CIRCUIT DRIVE MOTOR WIRING
772 STALLED TRACTION MOTOR OR POWER
WIRING ERROR
773 CAPACITOR BANK FAULT - CHECK
POWER CIRCUITS
774 SHORT CIRCUIT FIELD WIRING
775 OPEN CIRCUIT FIELD WIRING
776 STALLED PUMP MOTOR OR POWER
WIRING ERROR
3121221
SECTION 6 - GENERAL SPECIFICATIONS AND OPERATOR MAINTENANCE
DESCRIPTION
An accessory module is reporting a fault.
DESCRIPTION
The power module detected a problem in
the drive motors' power circuit wiring.
The power module detected a problem in
the drive motors' power circuit wiring.
The power module detected a problem in
the pump or drive motors' power circuit wir-
ing.
The power module detected a problem in
the drive motors' power circuit wiring.
The power module detected a problem in
the drive motors' power circuit wiring.
The power module detected a problem in
the drive motors' power circuit wiring.
– JLG Lift –
CHECK
• See accessory module documentation for troubleshooting.
Refer problem to a qualified JLG mechanic.
CHECK
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.
Refer problem to a qualified JLG mechanic.
6-23